Text version of the page
Text version of the page
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | © Siemens AG 2007 | | | | | | | | | | SITRANS P measuring instruments for pressure Transmitters for gage pressure for the paper industry | | | | | | | | | | RANS P300 and DS III series ith PMC connection - Technical descripti | | | | | | | | | | Parameterization through PROFIBUS PA interface Fully digital communication through PROFIBUS PA, profile 3.0, is particularly user-friendly. The PROFIBUS puts the DS III PA is in connection with a process control system, e.g. SIMATIC PSC 7. Communication is possible even in a potentially explosive environment. For parameterization through PROFIBUS you need suitable software, e.g. SIMATIC PDM (Process Device Manager). Parameterization through FOUNDATION Fieldbus Interface Fully digital communication through FOUNDATION Fieldbus is particularly user-friendly. Through the FOUNDATION Fieldbus the DS III Ff is connected to a process control system. Communication is possible even in a potentially explosive environment. For parameterization through the FOUNDATION Fieldbus you need suitable software, e.g. National Instruments Configurator. Adjustable parameters for DS III PA and FF and P300 PA and FF | | | | | | 2 | | | | | | | | | | When parameterizing with a PC, the connection is made through a HART modem. The signals needed for communication in conformity with the HART 5.x or 6.x protocols are superimposed on the output current using the Frequency Shift Keying (FSK) method. Adjustable parameter DS III HART and P300 HART | | | | | | | | | | | | | | | | | | | | | Adjustable parameters | Input keys PROFIBUS PA and FOUNDATION Fieldbus interface | | | | Electrical damping | xx | | | | Zero adjustment (correction of position) | xx | | | | Key and/or function disabling | xx | | | | Source of measured-value display | xx | | | | Physical dimension of display | xx | | | | Position of decimal point | xx | | | | Bus address | xx | | | | Adjustment of characteristic | xx | | | | Input of characteristic | x | | | | Freely-programmable LCD | x | | | | Diagnostic functions | x | | | | Diagnostic functions for DS III PA and FF and P300 PA | | | | | | | | | | | | | | | | | | | | | | | | | Parameters | Input keys | HART communication | | | | Start of scale | x | x | | | | Full-scale value | x | x | | | | Electrical damping | x | x | | | | Start-of-scale value without application of a pressure ("Blind setting") | xx | | | | Full-scale value without application of a pressure ("Blind setting") | xx | | | | Zero adjustment | x | x | | | | Current transmitter | x | x | | | | Fault current | x | x | | | | Disabling of keys, write protection | x | x1) | | | | Type of dimension and actual dimension | x | x | | | | Characteristic (linear) | x | x | | | | Input of characteristic | | x | | | | Freely-programmable LCD | | x | | | | Diagnostics functions | | x | | | | | | | | | | | | | | | | | | • Event counter • Slave pointer • Maintenance timer • Simulation functions • Display of zero correction • Limit transmitter • Saturation alarm Physical dimensions available for the display | | | | | | | | | | 1) Cancel apart from write protection Diagnostic functions for DS III HART and P300 HART | | | | | | | | | | Zero correction display Event counter Limit transmitter Saturation alarm Slave pointer Simulation functions Maintenance timer | | | | | | | | | | Physical variable | | Physical dimensions | | | | | | | | | | Pressure (setting can also be made in the factory) | | MPa, kPa, Pa, bar, mbar, torr, atm, psi, g/cm2, kg/cm2, mmH2O, mmH2O (4 °C), inH2O, inH20 (4 °C), ftH2O (20 °C), mmHg, inHg m, cm, mm, ft, in, yd g, kg, t, lb, Ston, Lton, oz m3, dm3, hl, yd3, ft3, in3, US gallon, lmp, gallon, bushel, barrel, barrel liquid K, °C, °F, °R % | | | | | | | | | | | | | | Available physical units of display for DS III HART and P300 HART | | | | | | Level (height data) Mass Volume | | | | | | Physical variable | | Physical dimensions | | | | | | | | | | Pressure (setting can also be made in the factory) | | Pa, MPa, kPa, bar, mbar, torr, atm, psi, g/cm2, kg/cm2, inH2O, inH2O (4 °C), mmH2O, ftH2O (20 °C), inHg, mmHg m, cm, mm, ft, in m3, dm3, hl, yd3, ft3, in3, US gallon, lmp, gallon, bushel, barrel, barrel liquid g, kg, t, lb, Ston, Lton, oz K, °C, °F, °R %, mA | | | | | | | | | | | | | | Temperature Miscellaneous | | | | | | Level (height data) Volume Mass Temperature Miscellaneous | | | | | | | | | | | | | | | | | | 2/46 | | | | | | Siemens FI 01 • 2008 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|