SITRANS P measuring instruments for pressure
Transmitters for gage pressure for the paper industry
RANS P300 and DS III series ith PMC connection - Technical descripti
Parameterization through PROFIBUS PA interface
Fully digital communication through PROFIBUS PA, profile 3.0, is particularly user-friendly. The PROFIBUS puts the DS III PA is in connection with a process control system, e.g. SIMATIC PSC 7. Communication is possible even in a potentially explosive envi­ronment.
For parameterization through PROFIBUS you need suitable soft­ware, e.g. SIMATIC PDM (Process Device Manager).
Parameterization through FOUNDATION Fieldbus Interface
Fully digital communication through FOUNDATION Fieldbus is particularly user-friendly. Through the FOUNDATION Fieldbus the DS III Ff is connected to a process control system. Commu­nication is possible even in a potentially explosive environment.
For parameterization through the FOUNDATION Fieldbus you need suitable software, e.g. National Instruments Configurator.
Adjustable parameters for DS III PA and FF and P300 PA and FF
2
HART communication between a PC communicator and a pressure transmitter
When parameterizing with a PC, the connection is made through a HART modem.
The signals needed for communication in conformity with the HART 5.x or 6.x protocols are superimposed on the output cur­rent using the Frequency Shift Keying (FSK) method.
Adjustable parameter DS III HART and P300 HART
Adjustable parameters
Input keys PROFIBUS PA and FOUNDATION Fieldbus interface
Electrical damping
xx
Zero adjustment (correction of position)
xx
Key and/or function disabling
xx
Source of measured-value dis­play
xx
Physical dimension of display
xx
Position of decimal point
xx
Bus address
xx
Adjustment of characteristic
xx
Input of characteristic
x
Freely-programmable LCD
x
Diagnostic functions
x
Diagnostic functions for DS III PA and FF and P300 PA
Parameters
Input keys
HART com­munication
Start of scale
x
x
Full-scale value
x
x
Electrical damping
x
x
Start-of-scale value without application of a pressure ("Blind setting")
xx
Full-scale value without application of a pressure ("Blind setting")
xx
Zero adjustment
x
x
Current transmitter
x
x
Fault current
x
x
Disabling of keys, write protection
x
x1)
Type of dimension and actual dimension
x
x
Characteristic (linear)
x
x
Input of characteristic
x
Freely-programmable LCD
x
Diagnostics functions
x
• Event counter
• Slave pointer
• Maintenance timer
• Simulation functions
• Display of zero correction
• Limit transmitter
• Saturation alarm
Physical dimensions available for the display
1) Cancel apart from write protection
Diagnostic functions for DS III HART and P300 HART
Zero correction display Event counter Limit transmitter Saturation alarm Slave pointer Simulation functions Maintenance timer
Physical variable
Physical dimensions
Pressure (setting can also be made in the factory)
MPa, kPa, Pa, bar, mbar, torr, atm, psi, g/cm2, kg/cm2, mmH2O, mmH2O (4 °C), inH2O, inH20 (4 °C), ftH2O (20 °C), mmHg, inHg
m, cm, mm, ft, in, yd
g, kg, t, lb, Ston, Lton, oz
m3, dm3, hl, yd3, ft3, in3, US gallon, lmp, gallon, bushel, barrel, barrel liquid
K, °C, °F, °R
%
Available physical units of display for DS III HART and P300 HART
Level (height data)
Mass
Volume
Physical variable
Physical dimensions
Pressure (setting can also be made in the factory)
Pa, MPa, kPa, bar, mbar, torr, atm, psi, g/cm2, kg/cm2, inH2O, inH2O (4 °C), mmH2O, ftH2O (20 °C), inHg, mmHg
m, cm, mm, ft, in
m3, dm3, hl, yd3, ft3, in3, US gallon, lmp, gallon, bushel, barrel, barrel liquid
g, kg, t, lb, Ston, Lton, oz
K, °C, °F, °R %, mA
Temperature Miscellaneous
Level (height data) Volume
Mass
Temperature Miscellaneous
2/46
Siemens FI 01 • 2008
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-100
101-150
151-200
201-222
pdf-page pdf di En 2008-10-41-10