SITRANS P measuring instruments for pressure
Transmitters for gage and absolute pressure
SITRANS P300
HART communication
HART communication Protocol
Software for computer
Communication FOUNDATION Fieldbus
Function blocks
3 function blocks analog input, 1 function block PID
230 ... 1100 Q HART Version 5.x SIMATIC PDM
Analog input
Adaptation to customer-specif- Yes, linearly rising or falling char-
ic process variables
acteristic
PROFIBUS PA communication
Simultaneous communication with master class 2 (max.)
The address can be set using
Electrical damping T63 , adjust- 0 ... 100 s able
4
Simulation function
Output/input (can be locked within the device with a bridge)
Can be parameterized (last good value, substitute value, incorrect value)
Yes, one upper and lower warning limit and one alarm limit respec­tively
Yes
Configuration tool or local opera­tion (standard setting address 126)
Failure mode
Cyclic data usage
• Output byte
• Input byte
Internal preprocessing Device profile
Function blocks
• Analog input
5 (one measuring value) or 10 (two measuring values)
0, 1, or 2 (register operating mode and reset function for metering)
Limit monitoring
- Square-rooted characteristic for flow measurement
• PID
• Physical block Transducer blocks
Standard FF function block
1 Resource block
1 transducer block Pressure with calibration, 1 transducer block
LCD
PROFIBUS PA Profile for Process control Devices Version 3.0, Class B
2
- Can be calibrated by applying two pressures
- Monitoring of sensor limits
Adaptation to customer-specif­ic process variables
Yes, linearly rising or falling char­acteristic
Yes
Electrical damping T63 , adjust- 0 ... 100 s able
Yes
Constant value or over parameter-
- Simulation function
- Failure mode
- Limit monitoring
• Register (totalizer)
- Failure mode
- Limit monitoring
• Physical block Transducer blocks
• Pressure transducer block
- Can be calibrated by applying two pressures
- Monitoring of sensor limits
- Specification of a container characteristic with
- Square-rooted characteristic for flow measurement
- Gradual volume suppression and implementation point of square-root extraction
- Simulation function for mea­sured pressure value and sen­sor temperature
Input /Output
Can be parameterized (last good value, substitute value, incorrect value)
Yes, one upper and lower warning limit and one alarm limit respec­tively
Can be reset, preset, optional direction of counting, simulation function of register output
Can be parameterized (summation with last good value, continuous summation, summation with incor­rect value)
One upper and lower warning limit and one alarm limit respectively
Simulation function: Measured
pressure value, sensor temper- izable ramp function ature and electronics tempera­ture
2
Yes Yes
Max. 30 nodes
Yes
Parameterizable
Constant value or over parameter-izable ramp function
2/34
Siemens FI 01 • 2008
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-100
101-150
151-200
201-222
pdf-page pdf di En 2008-10-41-11