| | | © Siemens AG 2007 | | |
| | | |
| | | SITRANS P measuring instruments for pressure | | |
| | | |
| | | SITRANS P Compact for gage and absolute pressure | | |
| | | |
| | | Selection and Ordering data | | Order No. | | Ord. code | | Selection and Ordering data | | Order No. | | Ord. code | | |
| | | 2 | | |
| | | | |
| | | |
| | | SITRANS P Compact pressure transmitters for pressure and absolute pressure with clamp-on remote seal 2-wire system Process temperature up to 140 °C (284 °F) Accuracy: 0.2% of full-scale value Output 4 ... 20 mA | | 7MF8 010 | | SITRANS P Compact pressure transmitters for pressure and absolute pressure with clamp-on remote seal 2-wire system Process temperature up to 140 °C (284 °F) Accuracy: 0.2% of full-scale value Output 4 ... 20 mA | | 7MF8010- | | |
| | | |
| | | | |
| | | 2■■■■-■■■■ ■■■ | | | 2■■■■-■■■■ ■■■ | | |
| | | | |
| | | |
| | | | | | | | | | | | | Measured range | Overload pressure | | | | | | | (continued) | | | | | | | | -1 ... 0 bar g | 10 bar g | | | A | | | | (-14.5 ... 0 psi g) | (145 psi g) | | | | | | | -1 ... 0.6 bar g | 10 bar g | | | B | | | | (-14.5 ... 8.7 psi g) | (145 psi g) | | | | | | | -1 ... 1.5 bar g | 16 bar g | | | C | | | | (-14.5 ... 21.8 psi g) | (232 psi g) | | | | | | | -1 ... 3 bar g | 16 bar g | | | D | | | | (-14.5 ... 43.5 psi g) | (232 psi g) | | | | | | | -1 ... 5 bar g | 30 bar g | | | E | | | | (-14.5 ... 72.5 psi g) | (435 psi g) | | | | | | | -1 ... 9 bar g | 30 bar g | | G A | | | | (-14.5 ... 130.5 psi g)(435 psi g) | | | | | | | -1 ... 15 bar g | 50 bar g | | GB | | | | (-14.5 ... 217.6 psi g)(725 psi g) | | | | | | | 0... 1bar a | 10 bar a | F) | HA | | | | (0 ... 14.5 psi a) | (145 psi a) | | | | | | | 0...1.6bar a | 10 bar a | F) | HB | | | | (0 ... 23.2 psi a) | (145 psi a) | | | | | | | 0...2.5bar a | 16 bar a | F) | HC | | | | (0 ... 36.3 psi a) | (232 psi a) | | | | | | | 0...4bar a | 16 bar a | F) | HD | | | | (0 ... 58 psi a) | (232 psi a) | | | | | | | 0... 6bar a | 30 bar a | F) | HE | | | | (0 ... 87 psi a) | (435 psi a) | | | | | | | 0 ... 10 bar a | 30 bar a | F) | J | A | | | | (0 ... 145 psi a) | (435 psi a) | | | | | | | Special version | | | Z | A | | | | (add Order code and plain text) | | | | | | | | | | | | | | | |
| | | Housing design (stainless steel mat. No. 1.4404/316L) / electr. connection Housing with angled plug to DIN 43650, IP65, union nut made of polyamide Housing with round plug M12, IP65, union nut made of polyamide Housing with round plug M12, IP65, union nut made of stainless steel Stainless steel field housing (small) with cable gland, IP67 Internal ventilation for measuring ranges < 10 bar (< 145 psi) Measured range Overload pressure | | |
| | | 3 | | |
| | | |
| | | |
| | | | | | | | | | | 0 ... 160 mbar g | 2bar g | B | | | | (0 ... 2.32 psi g) | (29 psi g) | | | | 0 ... 250 mbar g | 2bar g | B | | | | (0 ... 3.63 psi g) | (29 psi g) | | | | 0 ... 400 mbar g | 6bar g | B | | | | (0 ... 5.8 psi g) | (87 psi g) | | | | 0 ... 600 mbar g | 6bar g | B | | | | (0... 8.7 psi g) | (87 psi g) | | | | | 0 ... 1 bar g | 10 bar g | C | | | | (0 ... 14.5 psi g) | (145 psi g) | | | | 0 ... 1.6 bar g | 10 bar g | C | | | | (0 ... 23.2 psi g) | (145 psi g) | | | | 0 ... 2.5 bar g | 16 bar g | C | | | | (0 ... 36.3 psi g) | (232 psi g) | | | | 0 ... 4 bar g | 16 bar g | C | | | | (0 ... 58 psi g) | (232 psi g) | | | | 0 ... 6 bar g | 30 bar g | C | | | | (0...87 psi g) | (435 psi g) | | | | | 0 ... 10 bar g | 30 bar g | D | | | | (0 ... 145 psi g) | (435 psi g) | | | | 0 ... 16 bar g | 50 bar g | D | | | | (0 ... 232 psi g) | (725 psi g) | | | | 0 ... 25 bar g | 50 bar g | D | | | | (0 ... 363 psi g) | (725 psi g) | | | | 0 ... 40 bar g | 70 bar g | D | | | | (0 ... 580 psi g) | (1015 psi g) | | | | -160 ... 0 mbar g | 2bar g | E | | | | (-2.32 ... 0 psi g) | (29 psi g) | | | | -250 ... 0 bar g | 2bar g | E | | | | (-3.73 ... 0 psi g) | (29 psi g) | | | | -400 ... 0 bar g | 6bar g | E | | | | (-5.8 ... 0 psi g) | (87 psi g) | | | | -600 ... 0 bar g | 6bar g | E | | | | (-8.7... 0 psi g) | (87 psi g) | | | | | | | | | | | |
| | | |
| | | Explosion protection without with, to ATEX100a, II 2 G, EEx ib IICT6 | | |
| | | |
| | | Further designs Please add "-Z" to Order No. and specify Order code | | Order code | | |
| | | |
| | | |
| | | Hygiene version Roughness of process connection: Foil Ra < 0.8 Mm (3.15-10-8 inch): Welded seams Ra < 1.5 Mm (5.9-10-8 inch) Integral cooling element Process temperature max. 200 °C (392 °F) instead of 140 °C (284 °F) Connections for pipe Industrial pipes to DIN 11850 ISO pipes to ISO 2463 Pipes to O. D. Tubing "BS 4825 Part 1" Certificates | | P01 | | |
| | | |
| | | K01 | | |
| | | |
| | | R01 R02 R03 | | |
| | | |
| | | |
| | | |
| | | | | | | | | | Use of FDA-listed remote seal filling liq- | C17 | | | | uids certified by factory certificate | | | | | to EN 10204-2.2 | | | | | Roughness depth measurement Ra | C18 | | | | certified by factory certificate | | | | | to EN 10204-3.1 | | | | | Certification to EHEDG for clamp-on | C19 | | | | | | | | | to DIN 11864 | | | | | | | | | | |
| | | |
| | | F) Subject to export regulations AL: 9I999, ECCN: N. | | |
| | | |
| | | Siemens FI 01 • 2008 | | 2/19 | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |