Catalogue Siemens - Measuring instruments for pressure
www.siemens.com/processautomation
print switch display
Page / 222
Make a request   
SIEMENS Process Instrumentation - 81221, 145239, 81469, 148994, 81673, 81573, 81621
/ 222
See other catalogues for SIEMENS Process Instrumentation
Text version of the page
© Siemens AG 2007
SITRANS P measuring instruments for pressure
Industrial transmitters for gage and absolute pressure
• Upper and lower current saturation limit
• Electrical damping
The other two keys are used to set the values in the individual op­erating modes.
Two LED industrial indicators are fitted above the display to monitor the set range and the status.
The green LED signals that the measured pressure lies within the set limits. The red LED industrial lights up when the measured pressure lies outside the set limits and when there is an error.
I Technical specifications SITRANS P industrial pressure transmitters, ZD series Mode of operation
Rated conditions
Ambient conditions
• Ambient temperature
• Storage temperature Medium conditions
• Process temperature Degree of protection Electromagnetic compatibility
• Emitted interference and interfer­ence immunity
-25 ... +85 °C (-13 ... +185 °F) -40 ... +85 °C (-40 ... +185 °F)
-30 ... +100 °C (-22 ... +212 °F) IP65 to EN 60529
To EN 61326/A1 appendix A
(1998)
Industrial displays and controls
Display
Decimal point
Limit values
Limit violation display
LCD, max. 5 digits, digit height 9 mm
Freely parameterizable
Freely parameterizable
Red LED and message on LCD (t symbol /4 symbol in case of limit violation in upward / down­ward direction)
With 3 keys
mA or % or physical variable (default setting: bar)
Other dimensions: mbar, kPa, MPa, mmH20, mH20, psi, inH20, mmHg, kg/cm2, torr, atm Between 0.1 and 100 s (increment: 0.1 s) freely parame-terizable
Measuring principle
Thin-film strain gage
Input
Measured variable
Measured range
0 ... 2 bar (0 ... 29 psi)
0 ... 10 bar (0 ... 145 psi)
0 ... 50 bar (0 ... 725 psi)
0 ... 200 bar (0 ... 2900 psi)
0 ... 400 bar (0 ... 5800 psi)
Measured range
0 ... 2 bar (0 ... 29 psi)
0 ... 10 bar (0 ... 145 psi)
0 ... 50 bar (0 ... 725 psi)
0 ... 200 bar (0 ... 2900 psi)
0 ... 400 bar (0 ... 5800 psi)
Range adjustment (turndown)
Gage and absolute pressure Resolution
0.6 mbar (0.008 psi) 3 mbar (0.044 psi) 15 mbar (0.218 psi) 60 mbar (0.9 psi) 120 mbar (1.8 psi) Overload limit 5 bar (72.5 psi) 25 bar (363 psi) 120 bar (1740 psi) 500 bar (7250 psi) 600 bar (8700 psi) 5:1
Parameterization Units
Damping
Design
Weight
Electrical connection Process connection
«0.6 kg (=1.32 lb)
Using 2-pole plug connector with M16x1.5-Cable inlet to
EN 175301-803A, plastic
• Male thread G1/B and female thread G1/8B
• G1/B to EN 837-1
• Female thread: /-14 NPT
1 Radial (type A), can be swiveled by max. ±120° (a)
Axial (type B), can be swiveled by max. ±360°
Output
Output signal Lower current limit Upper current limit Output protected against
Max. load
Voltage measurement
4 ... 20 mA min. 3.6 mA max. 23 mA
Reversed polarity, overvoltage and short-circuiting
R B = (UH-12V) / 0.023 A
Linear rising
Version of housing/process connec­tion
Material
Non-wetted parts materials
• Field housing
• Cover
Wetted parts materials
• Measuring cell
• Gasket
• Process connection
Measuring accuracy
Error in measurement (including non-linearity, hysteresis and repeat­ability, at 25 °C (77 °F))
Adjustment time
Long-term drift
Influence of ambient temperature Vibration influence Power supply effect
To EN 60770-1
< 0.25% of full-scale value (typi­cal), max. 0.5%
0 80 mm (3.15 inch), stainless steel mat. No. 1.4016
Stainless steel, mat. No. 1.4016 with glass
< 100 ms
0.25% of full scale value/year
< ±0.25%/10 K (< ±0.25%/10 K) of full-scale value
0.05%/g to 500 Hz in all directions (to IEC 68-2-64)
< ±0.01%/V of full-scale value
Al2O3
Viton
Stainless steel, mat. No.
1.4571/316Ti
Power supply
Terminal voltage on pressure trans­mitter (UH)
12 ... 30 VDC
Certificate and approvals
Classification according to pressure equipment directive 97/23/EC
For gases of fluid group 1 and liq­uids of fluid 1; complies with requirements of article 3, para­graph 3 (sound engineering prac­tice)
2/12
Siemens FI 01 • 2008
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-100
101-150
151-200
201-222
pdf-page pdf di En 2008-10-41-11