Level instruments

Point level metering - Capacitance switches

Pointek CLS500 5/52

Selection and Ordering data

Order No.

Selection and Ordering data

Order No. Pointek CLS500 High temperature 7 M L 5 6 4 - Pointek CLS500 High temperature 7 M L 5 6 4 - Inverse frequency shift capacitance level switch for detecting interfaces, solids, liquids, toxic and aggressive chemicals in critical conditions of extreme temperature and pressure.
7 A
77 7 -
7 7 7 7 Inverse frequency shift capacitance level switch for detecting interfaces, solids, liquids, toxic and aggressive chemicals in critical conditions of extreme temperature and pressure.
7 A
77 7 -
7 7 7 7 Electronic transmitter Approvals No transmitter supplied General Purpose A MSP2002-1 (330 pF) 1 CSA/FM Class I, Div. 2, Groups A, B, C, D T4;ATEX II 3G 2D EEx nA [ib] IIC T6 to T4 T100 °C; CSA/FM Class II and III Div. 1, Groups E, F, GT4 B Process connection and pressure rating 316L stainless steel, raised face
1) 2" ASME, 150 lb A1 ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 °C D 2" ASME, 300 lb A2 FM Class I, Div. 1, Groups A, B, C, D T4 F 2" ASME, 600 lb A3 Probe/electrode diameter 2" ASME, 900 lb A4 Maximum length 1000 mm (39.37")
7) A 3" ASME, 150 lb B1 Thermal isolator/remote version 3" ASME, 300 lb
2) B2 Rigid thermal isolator [for process temperature over +85 °C (+185 °F)] 1 3" ASME, 600 lb
2) B3 3" ASME, 900 lb
2) B4 Further designs Order code 4" ASME, 150 lb
2) C1 4" ASME, 300 lb
2) C2 Please add " -Z " to Order No. and specify Order code(s). 4" ASME, 600 lb
2) C3

5

4" ASME, 900 lb
2) C4 Insertion length, specify in plain text: Y01: ... mm Y01 for probe insulation option 1: min. = 200 mm (7.87")Y01 for probe insulation option 2: min. = 200 mm (7.87") Y01 6" ASME, 150 lb
2) D1 6" ASME, 300 lb
2) D2 6" ASME, 600 lb
2) D3 6" ASME, 900 lb
2) D4 Active Shield length, specify in plain text: Y02 Y02: ... mm 316L stainless steel, Type B1 raised face
3) Y02 for probe insulation option 1: min. = 105 mm (4.13") Y02 for probe insulation option 2: min. = 100 mm (3.94") DN 50 PN16 E1 DN 50 PN25 E2 DN 50 PN40 E3 Stainless steel tag [69 x 38 mm (2.7 x 1.5")]: Mea- suring-point number/identification (max. 20 charac- ters); specify in plain text Y15 DN 50 PN63 E4 DN 80 PN16 F1 DN 80 PN25 F2 Acceptance test certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and ISO 9000 C11 DN 80 PN40
2) F3 DN 80 PN63
2) F4 Inspection Certificate Type 3.1 per EN 10204 C12 DN 100 PN16
2) G1 Instruction manual See page 5/52 DN 100 PN25
2) G2 DN 100 PN40
2) G3 Accessories See page 5/52 DN 100 PN63
2) G4
1) Welded flange for no insulation option only 2) DN 125 PN16
2) H1
Custom shipping methods required. Contact factory for more details. 3) DN 125 PN25
2) H2
Flat faced flange for no insulation option only 4) DN 125 PN40
2) H3
Non-conductive material only, stainless steel non-insulated probe diameter 19 mm (0.75") DN 125 PN63
2) H4
5) Enamel insulated probe diameter 16 mm (0.63") (Note: Flange bolting patterns and facings dimen- sionally correspond to the applicable ASME B16.5 or EN 1092-1 standard.)
6) Single piece construction for enamel option only 7) Add order code Y01 and Y02 in plain text: “Insertion/active shield length ... mm"Minimum insertion length depends on probe version selected. See dimen-sion drawings on page 5/59 for more details. Probe insulation/material of process connection No insulation/316L stainless steel
4) 7) 1 Enamel insulation/316L stainless steel
5) 6) 7) 2

Selection and Ordering data

Order No. Stilling well No stilling well Instruction manual English 7ML1998-5GG01 German 7ML1998-5GG31 French 7ML1998-5GG11 DutchNote: The instruction manual should be ordered as a separate line on the order. 7ML1998-5GG41 This device is shipped with the Siemens Milltronics manual CD containing the complete ATEX Quick Start and instruction manual library. Accessories Transmitter, MSP 2002-1, 330 PF
1) L) 7ML1830-1JP
1) Industrial transmitters not suitable for Intrinsically Safe application (ATEX II 1G EEx ia IIC T4 or CSA/FM Class 1 Div 1 Grp A, B, C and D) L) Subject to export regulations AL: N, ECCN: 3A991X Siemens FI 01 · 2009
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 51 p.51
page 52 p.52
page 53 p.53
page 54 p.54
page 55 p.55
page 56 p.56
page 57 p.57
page 58 p.58
page 59 p.59
page 60 p.60
page 61 p.61
page 62 p.62
page 63 p.63
page 64 p.64
page 65 p.65
page 66 p.66
page 67 p.67
page 68 p.68
page 69 p.69
page 70 p.70
page 71 p.71
page 72 p.72
page 73 p.73
page 74 p.74
page 75 p.75
page 76 p.76
page 77 p.77
page 78 p.78
page 79 p.79
page 80 p.80
page 81 p.81
page 82 p.82
page 83 p.83
page 84 p.84
page 85 p.85
page 86 p.86
page 87 p.87
page 88 p.88
page 89 p.89
page 90 p.90
page 91 p.91
page 92 p.92
page 93 p.93
page 94 p.94
page 95 p.95
page 96 p.96
page 97 p.97
page 98 p.98
page 99 p.99
page 100 p.100
Pages:
1-50
51-100
101-150
151-200
201-250
251-296
pdf-page pdf di En 2009-01-02-08