© Siemens AG 2007 SITRANS L Level instruments
Pointek CLS500
5/51
Selection and Ordering data
Order No. >
Selection and Ordering data
Order No. PointekCLS500, single piece flange 7 M L 5 6 3 - PointekCLS500, single piece flange 7 M L 5 6 3 - Inverse frequency shift capacitance
level switch manufacturer for detecting interfaces, solids, liquids, toxic and aggressive chemicals in critical conditions of extreme temperature and pressure. >
7 77 77 - >
77 A Inverse frequency shift capacitance level switch for detecting interfaces, solids, liquids, toxic and aggressive chemicals in critical conditions of extreme temperature and pressure. >
7 77 77 - >
77 A Electronic transmitter Further designs Order code No transmitter supplied Please add " -Z " to Order No. and specify Order code(s). MSP2002-1 (330 pF) 1 Process connection and pressure rating Insertion length, specify in plain text: Y01: ... mm [minimum 200 mm (7.87")] Y01 Single piece flange, 316L stainless steel, raised face Active Shield length - minimum length is 50mm. Y02: ... mm Y02 2" ASME, 150 lb A A >
3) 2" ASME, 300 lb A B Stainless steel tag [69 x 38 mm (2.7 x 1.5")]: Mea-suring-point number/identification (max. 20 charac-ters); specify in plain text Y15 3" ASME, 150 lb B A 3" ASME, 300 lb >
1) B B Acceptance test certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and ISO 9000 C11 4" ASME, 150 lb >
1) C A 4" ASME, 300 lb >
1) C B Inspection Certificate Type 3.1 per EN 10204 C12 6" ASME, 150 lb >
1) D A 6" ASME, 300 lb >
1) D B Instruction manual See page 5/52 Single piece flange, 316L stainless steel, Type B1 Accessories See page 5/52 raised faced >
1) Custom shipping methods required. Contact factory for more details. DN 50 PN16 E C >
2) 5
Barrier required for Intrinsically Safe protection DN 50 PN25 E D >
3) See dimension drawings on page 5/59 for further explanation of Y02. DN 80 PN16 F C DN 80 PN25 F D DN 100 PN16 >
1) G C DN 100 PN25 >
1) G D DN 125 PN16 >
1) H C DN 125 PN25 >
1) (Note: Flange bolting patterns and facings dimen-
sionally correspond to the applicable ASME B16.5 or EN 1092-1 standard.) H D Probe insulation/material of process connection PFA insulation/316L stainless steel 1 Approvals General Purpose 1 CSA/FM Class I, Div. 2, Groups A, B, C, D T4;
ATEX II 3GD 2D EEx nA [ib] IIC T6 to T4 T100 °C; CSA/FM Class II and III Div. 1, Groups E, F, G;ATEX II 1/2 GD EEx d [ia] T6 to T1 2 CSA/FM ClassI, Div. 1, Groups A, B, C, D, T4; ATEX II 1G EEx [ia] IIC T6 to T4 >
2) 3 ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 4 FM Class I, Div. 1, Groups A, B, C, D, T4 6 Probe/electrode diameter 16 mm (0.63”) rigid rod, maximum length 1000 mm (39.4”) (Y01) 1 Thermal isolator/remote version Rigid thermal isolator [for process temperature over +85 °C (+185 °F)] A No thermal isolator B Siemens FI 01 · 2008 >