© Siemens AG 2007 SITRANS L Level instruments
Pointek CLS500
5/50
Selection and Ordering data
Order No. >
Selection and Ordering data
Order No. Pointek CLS500, threaded 7 M L 5 6 1 - Pointek CLS500, welded flange 7 M L 5 6 2 - Inverse frequency shift capacitance
level switch for detecting interfaces, solids, liquids, toxic and aggressive chemicals in critical conditions of extreme temperature and pressure. >
7 7 77 7 - >
7 7 A Inverse frequency shift capacitance level switch for detecting interfaces, solids, liquids, toxic and aggressive chemicals in critical conditions of extreme temperature and pressure. >
777 77 - >
77 A Electronic transmitter Electronic transmitter No transmitter supplied No transmitter supplied MSP2002-1 (330 pF) 1 MSP2002-1 (330 pF) 1 Process connection Process connection and pressure rating ¾" A Welded flange, 316L stainless steel, raised face 1" B 2" ASME, 150 lb A A 1¼" C 2" ASME, 300 lb A B 1½" D 3" ASME, 150 lb B A 2" E 3" ASME, 300 lb >
1) B B >
1) Threaded connection and rating 4" ASME, 150 lb C A >
1) NPT [(Taper), ANSI/ASME B1.20.1] A 4" ASME, 300 lb C B R [(BSPT), EN 10226/PT (JIS-T) JIS B 0203] B 6" ASME, 150 lb >
1) D A G [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] D 6" ASME, 300 lb >
1) D B Welded flange, 316L stainless steel, Type A flat >
5
Probe insulation/material of process connection PFA insulation/316L stainless steel 1 faced DN 50 PN16 E C Approvals DN 50 PN25 E D General Purpose 1 CSA/FM Class I, Div. 2, Groups A, B, C, D T4;ATEX II 3GD 2D EEx nA [ib] IIC T6 to T4 T100 °C; CSA/FM Class II and III Div. 1, Groups E, F, G;
ATEX II 1/2 GD EEx d [ia] T6 to T1 2 DN 80 PN16 F C DN80 PN25 F D DN 100 PN16 >
1) G C DN 125 PN16 >
1) H C CSA/FM ClassI, Div. 1, Groups A, B, C, D, T4; ATEX II 1G EEx [ia] IIC T6 to T4 >
1) 3 (Note: Flange bolting patterns and facings dimen-
sionally correspond to the applicable ASME B16.5 or EN 1092-1 standard.) ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 4 FM Class I, Div. 1, Groups A, B, C, D, T4 6 Probe insulation/material of process connection Probe/electrode diameter PFA insulation/316L stainless steel 1 16 mm (0.63”) rigid rod, minimum insertion length 200 mm (7.9”), maximum insertion length 1000 mm (39.4”) 1 Approvals >
2) General Purpose 1 CSA/FM Class I, Div. 2, Groups A, B, C, D T4;
ATEX II 3GD 2D EEx nA [ib] IIC T6 to T4 T100 °C; CSA/FM Class II and III Div. 1, Groups E, F, G;
ATEX II 1/2 GD EEx d [ia] T6 to T1 2 Thermal isolator/remote version Rigid thermal isolator [for process temperature over +85 °C (+185 °F)] A No thermal isolator B CSA/FM ClassI, Div. 1, Groups A, B, C, D, T4; ATEX II 1G EEx [ia] IIC T6 to T4 >
2) 3 Further designs Order code ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 4 Please add " -Z " to Order No. and specify Order code(s). FM Class I, Div. 1, Groups A, B, C, D, T4 6 Probe/electrode diameter Insertion length, specify in plain text: Y01 Y01: ... mm [minimum 200 mm (7.87")] 16 mm (0.63”) rigid rod, min. length 200 mm (7.9”), max. length 1000 mm (39.4”) 1 Active Shield length - minimum length is 50mm. Y02 Y02: ... mm Thermal isolator/remote version Stainless steel tag [69 x 38 mm (2.7 x 1.5")]: Mea-suring-point number/identification (max. 20 charac-
ters); specify in plain text Y15 Rigid thermal isolator [for process temperature over +85 °C (+185 °F)] A No thermal isolator B Inspection Certificate Type 3.1 per EN 10204 C12 Further designs Order code Instruction manual See page 5/52 Please add " -Z " to Order No. and specify Order code(s). Accessories See page 5/52 >
1) Insertion length, specify in plain text: Y01: ... mm [minimum 200 mm (7.87")] Y01 >
Barrier required for Intrinsically Safe protection 2) Add order code Y01 and Y02 in plain text:“Insertion/active shield length ... mm” Active Shield length - minimum length is 50mm. Y02: ... mm >
3) Y02 Stainless steel tag [69 x 38 mm (2.7 x 1.5")]: Mea-suring-point number/identification (max. 20 charac-
ters); specify in plain text Y15 Acceptance test certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and ISO 9000 C11 Inspection Certificate Type 3.1 per EN 10204 C12 Instruction manual See page 5/52 Accessories See page 5/52 >
1) Custom shipping methods required. Contact factory for more details. 2) Barrier required for Intrinsically Safe protection 3) See dimension drawings on page 5/59 for further explanation of Y02. Siemens FI 01 · 2008 >