Level instruments

Point level measurement - Capacitance switches

Pointek CLS500 5/49

Certificates and approvals •General Purpose CE (complies with E.C.C. require-ments of EN 55011 and EN 61326)•Non incendive/Non sparking •CSA/FM Class I, Div. 2, Groups A, B, C, D T4 •ATEX II 3G 2D EEx n A [ib] IIC T6 to T4 T100 °C •Dust Ignition Proof •CSA/FM Class II and III, Div. 1, Groups E, F, G T4 •ATEX II 1/2 GD EEx d [ia] T6 to T1 T100 °C •Explosion Proof •FM Class 1, Div. 1, Groups A, B, C, D T4 •ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 °C •Marine Lloyds Register of Shipping, Cat-egories ENV1, ENV2, ENV3, ENV5 •Pressure PED 97/23/EC, CSA B51•Other C-TICK (Australia)
1) When operation is in areas classified as hazardous, observe restrictions according to relevant certificate. See also Pressure/Temperature curves on page 5/53.

5

Standard Combinations

Pointek CLS500 probe version Standard HT SeriesProcess connection typesStandard (PFA)(7ML5601, 7ML5602, 7ML5603)High Temperature (Enamel or Stainless steel) (7ML5604) ThreadedAvailable as standard-FlangeAvailable as standardAvailable as standard Process connection materials 316L stainless steel Available as standardAvailable as standard Probe insulation None-HT Stainless: avail-able as standardPFAAvailable as standard– EnamelHT Enamel: available as standard Length parameters Max. rod length1000 mm (40")1000 mm (40") Process condtitions
1) Max. pressure 150 bar g (2175 psi g)Stainless steel:
2) 35 bar g (507 psi g)Enamel:
2) 345 bar g (5004 psi g)Max. temperature +200 °C (+392 °F)+400 °C (+752 °F)
1) When operation is in areas classified as hazardous, observe restrictions according to relevant certificate. See also Pressure/Temperature curves on page 5/53. 2) Pressure rating of process industrial seal is temperature dependent. See Pres- sure/Temperature curves on page 5/53.–Not available as standard Siemens FI 01 · 2009
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-100
101-150
151-200
201-250
251-296
pdf-page pdf di En 2009-01-02-08