Text version of the page
Level instruments
Continuous level metering - Guided wave radar industrial transmitters
SITRANS LG200
Coaxial Steam Probe (7ML1301-5)
Coaxial Interface Probe (7ML1301-6)
Single Rigid Rod Probe (7ML1303-1)
Single Rigid Rod HT/HP Probe (7ML1303-2)
Single Rigid Rod Probe, PFA rod insulation (7ML1303-1J)
Model reference number
7xS-x
7xT-x
7xF-x
7xJ-x
7xF-4
Recommended applications:
Hot water (steam) >+200 °C (+400 °F) (external chamber is required for use in boil­ers)
Liquid/liquid-interface, temperatures to +200 °C (+400 °F); clean, low-vis­cosity liquids
Coating and buildup, foam
Coating and buildup, foam
Excessive coating and buildup, foam
Not recommended
for:
General purpose, coat­ing and buildup, foam
Coating and buildup, foam
Low dielectric media (dK< 10)1)
Low dielectric media
(dK < 10)1)
Low dielectric media (dK < 10)1)
Materials/wetted parts
316L SS,
PEEK spacers, Aegis PF128 O-ring2)
316L S2S), TFE spacers, O-ring 2)
316L SS, PTFE, O-ring
2)
316L SS, TFE, O-ring 2)
316L SS, PFA, PTFE, O-ring2)
Aegis PF128 O-ring2), PEEK only
O-ring2)
O-ring2)
Aegi2s) PF128 O-ring
only2)
O-ring2)
Rod/Tube diameter:
Standard
0 8 mm (0.3125") rod 0 22 mm (0.875") tube
0 8 mm (0.3125") rod 0 22 mm (0.875") tube
0 12 mm (0.5") rod
0 12 mm (0.5") rod
0 12 mm (0.5") rod
0 16 mm (0.625") insulation
Enlarged
N/A
0 15 mm (0.63") rod 0 45 mm (1.75") tube
N/A
N/A
N/A
Process connection thread:
Standard
%" NPT [(Taper), ANSI/ASME B1.20.1], G 1" [(BSPP),
EN ISO 228-1]
%" NPT [(Taper), ANSI/ASME B1.20.1], G 1" [(BSPP),
EN ISO 228-1]
%" NPT [(Taper), ANSI/ASME B1.20.1], G 1" [(BSPP),
EN ISO 228-1]
%" NPT [(Taper), ANSI/ASME B1.20.1], G 1" [(BSPP),
EN ISO 228-1]
2" NPT [(Taper), ANSI/ASME B1.20.1], G 2" [(BSPP), EN ISO 228-1]
Enlarged
N/A
2" NPT [(Taper),
ANSI/ASME B1.20.1]
2" NPT [(Taper),
ANSI/ASME B1.20.1]
2" NPT [(Taper), ANSI/ASME B1.20.1]
N/A
Flange ASME
(EN/DIN):
1 to 4" (DN 25 to 100)
1 to 4" (DN 25 to 100)
2 to 4" (DN 50 to 100)
2 to 4" (DN 50 to 100)
2 to 4" (DN 50 to 100)
Standard Enlarged
N/A
2 to 4" (DN 50 to 100)
N/A
N/A
N/A
Length
60 to 455 cm (24 to 180")
60 to 610 cm (24 to 240")
60 to 610 cm (24 to 240")
60 to 610 cm (24 to 240")
60 to 610 cm (24 to 240")
Transition zone: Top
25 mm (1") @ dk > 10
none
Blocking distance: 12 to 91 cm (4.8 to 36"), probe length depen­dent
Blocking distance: 12 to 91 cm (4.8 to 36"), probe length depen­dent
Blocking distance: 12 to 91 cm (4.8 to 36"), probe length dependent
Transition zone:
25 mm (1") @ dk > 10
150 mm (6") @ dk = 1.4
25 mm (1") @ dk >10
25 mm (1") @ dk >10
25 mm (1") @ dk >10
Bottom
25 mm (1") @ dk = 80
Process
temperature
maximum
+343 °C @ 165 bar g
(+650 °F @ 2400 psi g) (saturated steam)
+200 °C @ 18 bar g (+400 °F @ 270 psi g)
+ 150 °C @ 27 barg (+300 °F @ 400 psi g)
+316 °C @ 165 bar g (+605 °F @ 2400 psi g)
+150 °C @ 27 bar g (+300 °F @ 400 psi g)
Process
-40 °C @ 207 bar g
-40 °C @ 70 bar g
-40 °C @ 70 bar g
-40 °C @ 70 bar g
-40 °C @ 50 bar g
temperature minimum
(-40 °F @ 3000 psi g)
(-40 °F @ 1000 psi g)
(-40 °F @ 1000 psi g)
(-40 °F @ 1000 psi g)
(-40 °F @ 750 psi g)
Process pressure maximum
165 barg@ +343 °C (2400 psi g @ +650 °F)
70 bar g @ +20 °C (1000 psi g @ +70°F)
70 bar g @ +20 °C (1000 psi g @ +70 °F)
207 bar g @ +20 °C (3000 psi g @ +70 °F)
70 bar g @ +20 °C (1000 psi g @ +70 °F)
Process pressure minimum/vacuum service
Yes, not hermetic
Yes, not hermetic
Not suitable
Not suitable
Not suitable
Dielectric range
10 to 100
Upper liquid layer 1.4 to 5 Interface liquid layer 15 to
100
1.9 to 1001)
1.9 to 1001)
1.9 to 1001)
Maximum viscosity
Standard Enlarged
500 cP N/A
500 cP 1500 cP
10000 cP (consult factory if severe agitation/turbulence)
Coating/buildup
No
No
Yes, maximum error 10% of coated length;% error related to dielectric of media, thickness of coating and coated probe length above media
Foam
No
No
Yes
Yes
Yes
Corrosives
Yes
Yes
Yes
Yes
Yes
Sanitary
No
No
No
No
No
Overfill
Yes
Yes
No
No
No
1) With dK of 1.9 to 10, the device must be mounted between 50 and 150 mm (2 to 6") of metal tank wall or in chamber/bridle
2) See O-ring Selection Professional guide for guidance
5/214
Siemens FI 01 • 2009
Modification 10/2008
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 201 p.201
page 202 p.202
page 203 p.203
page 204 p.204
page 205 p.205
page 206 p.206
page 207 p.207
page 208 p.208
page 209 p.209
page 210 p.210
page 211 p.211
page 212 p.212
page 213 p.213
page 214 p.214
page 215 p.215
page 216 p.216
page 217 p.217
page 218 p.218
page 219 p.219
page 220 p.220
page 221 p.221
page 222 p.222
page 223 p.223
page 224 p.224
page 225 p.225
page 226 p.226
page 227 p.227
page 228 p.228
page 229 p.229
page 230 p.230
page 231 p.231
page 232 p.232
page 233 p.233
page 234 p.234
page 235 p.235
page 236 p.236
page 237 p.237
page 238 p.238
page 239 p.239
page 240 p.240
page 241 p.241
page 242 p.242
page 243 p.243
page 244 p.244
page 245 p.245
page 246 p.246
page 247 p.247
page 248 p.248
page 249 p.249
page 250 p.250
Pages:
1-50
51-100
101-150
151-200
201-250
251-296
pdf-page pdf di En 2009-01-02-08