Catalogue Siemens - Level instruments
www.siemens.com/processautomation
print switch display
Page / 242
Make a request   
SIEMENS Process Instrumentation - 2739, 17489, 68351
/ 242
See other catalogues for SIEMENS Process Instrumentation
Text version of the page
© Siemens AG 2007
SITRANS L Level instruments
Continuous measurement - Radar transmitters
SITRANS Probe LR
1 Technical specifications
Mode of operation
Measuring principle
Pulse radar level measurement
Frequency
5.8 GHz (North America 6.3 GHz)
Measuring range
0.3 to 20 m (1.0 to 65 ft)
Output
Analog output
4 to 20 mA
Accuracy
± 0.02 mA
Span
Proportional or inversely propor-
tional
Communications
HART®
Performance (reference condi-
tions)
Accuracy
± the greater of 0.1% of range or
10 mm (0.4")
Influence of ambient temperature
0.003%/K
Repeatability
± 5 mm (2")
Fail-safe
mA signal programmable as high,
low or hold (LOE)
Rated operating conditions
• Installation conditions
- Location
Indoor/outdoor
• Ambient conditions (enclosure)
- Ambient temperature
-40 to +80 °C (-40 to +176 °F)
- Installation category
I
- Pollution degree
4
Medium conditions
Dielectric constant er
er > 1.6 (for er < 3, use stillpipe)
Vessel temperature
-40 to +80 °C (-40 to +176 °F)
Vessel pressure
3 bar g (43.5 psi g)
Design
• Enclosure
- Body construction
PBT (Polybutylene Terephthalate)
- Lid construction
PEI (Polyether Imide)
- Cable inlet
2 x M20x1.5 or 2 x /2" NPT with
adapter
• Degree of protection
Type 4X/NEMA 4X, Type 6/
NEMA 6, IP67, IP68
• Weight
1.97 kg (4.35 lb)
• Antenna
- Material
Polypropylene rod, hermetically
sealed construction
- Dimensions
Standard 100 mm (4") shield for
maximum 100 mm (4") nozzle manufacturer or
optional 250 mm (10") long shield
• Process connections
1/" NPT [(Taper), ANSI/ASME
B1.20.1]
R 1/" [(BSPT), EN 10226]
G 1/" [(BSPP), EN ISO 228-1]
Power supply
• Nominal 24 V DC with max.
550 Q, maximum 30 V DC
• 4 to 20 mA
Certificates and approvals
General
CSAUS/C, CE, FM
Marine
• Lloyd's Register of Shipping
• ABS Type Approval
Radio
FCC, Industry Canada and Euro-
pean (R&TTE)
Hazardous
• Europe
• USA
ATEX II 1G EEx la IIC T4
Intrinsically Safe barrier required FM Class I, Div.1, Groups A,B,C,D; Class II, Div. 1, Groups E,F, G; Class III
Intrinsically Safe barrier required CSA Class I, Div.1, Groups A,B,C,D; Class II, Div. 1, Group G; Class III
• Canada
Programming
Handheld communicator PC
Intrinsically safe Siemens Milltronics handheld programmer (optional)
• Approvals (handheld program­mer)
HART
SIMATIC PDM Infrared receiver
ATEX II 1G EEx ia IIC T4
CSA and FM Class I, Div.1, Groups A,B,C,D, T6 @ max. ambi­ent
Multi-segment alphanumeric liq­uid industrial crystal with bar graph (repre­senting level) available in four languages
Display (local)
5/151
Siemens FI 01 • 2008
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 151 p.151
page 152 p.152
page 153 p.153
page 154 p.154
page 155 p.155
page 156 p.156
page 157 p.157
page 158 p.158
page 159 p.159
page 160 p.160
page 161 p.161
page 162 p.162
page 163 p.163
page 164 p.164
page 165 p.165
page 166 p.166
page 167 p.167
page 168 p.168
page 169 p.169
page 170 p.170
page 171 p.171
page 172 p.172
page 173 p.173
page 174 p.174
page 175 p.175
page 176 p.176
page 177 p.177
page 178 p.178
page 179 p.179
page 180 p.180
page 181 p.181
page 182 p.182
page 183 p.183
page 184 p.184
page 185 p.185
page 186 p.186
page 187 p.187
page 188 p.188
page 189 p.189
page 190 p.190
page 191 p.191
page 192 p.192
page 193 p.193
page 194 p.194
page 195 p.195
page 196 p.196
page 197 p.197
page 198 p.198
page 199 p.199
page 200 p.200
Pages:
1-50
51-100
101-150
151-200
201-242
pdf-page pdf di En 2008-10-41-11