| | Version | MAG 1100 | MAG 1100 HT (High temperature) | |
| | Measuring principle Excitation frequency | Electromagnetic induction DN 2 ... 65 (1/12" ... 21/"): 12.5 Hz DN 80, 100 (3", 4"): 6.25 Hz | Electromagnetic induction DN 15 ... 50 (1" ... 2"): 12.5 Hz DN 80, 100 (3", 4"): 6.25 Hz | |
| | Process connection Nominal size • MAG 1100 (Ceramic) • MAG 1100 (PFA) Mating flanges | DN 2 ... DN 100 (1/12" ... 4") DN 10 ... DN 100 (3/8" ... 4") EN 1092-1 (DIN 2501), ANSI B 16.5 class 150 and 300 or equivalent Option: DN 2 ... 10 (1/12" ... 3/8"): | DN 15 ... DN 100 (1/" ... 4") EN 1092-1 (DIN 2501), ANSI B 16.5 class 150 and 300 or equivalent | |
| | Rated operating conditions Ambient conditions Ambient temperature^ • Sensor • Compact transmitter MAG 6000 I • Compact transmitter MAG6000IExd | -40 ... +100 °C (-40 ... +210 °F) -20 ... +50 °C (-4 ... +120 °F) -20 ... +60 °C (-4 ... +140 °F) -10 ... +60 °C (+14 ... +140 °F) | -40 ... +100 °C (-40 ... +210 °F) | |
| | Temperature of medium • MAG 1100 (Ceramic) • MAG 1100 (PFA) | -20 ... +150 °C (-4 ... +300 °F) -30 ... +130 °C (-20 ... +270 °F) Suitable for steam sterilization at 150 °C (300 °F) | -20 ... +200 °C (-4 ... +390 °F) | |
| | Temperature shock • MAG 1100 (Ceramic) - Duration < 1 min, followed by 10 min rest • MAG 1100 (PFA) | • DN 2, 3 (1/12", 1/8") No limitations • DN 6, 10, 15, 25: Max. AT < 80 °C/min (1V", 3/8", 1/", 1": Max. AT < 80 K/min) • DN 40, 50, 65: Max. AT < 70 °C/min (1/", 2", 2/": Max. AT < 70 K/min) • DN 80, 100: Max. AT < 60 °C/min (3", 4": Max. AT < 60 K/min) Max. ±100 °C (210 °F) momentarily | • DN 15, 25: Max. AT < 80 °C/min (/", 1": Max. AT < 80 K/min) • DN 40, 50: Max. AT < 70 °C/min (1/", 2": Max. AT < 70 K/min) • DN 80, 100: Max. AT < 60 °C/min (3", 4": Max. AT < 60 K/min) | |
| | Operating pressure • MAG 1100 (Ceramic) • MAG 1100 (PFA) | • DN 2 ... 65: 40 bar (1/12" ... 2/": 580 psi) • DN 80: 37.5 bar (3": 540 psi) • DN 100: 30 bar (4": 435 psi) Vacuum: 1 x 10-6 bar (1.5 x 10-5 psi) 20 bar (290 psi) Vacuum: 0.02 bar (0.3 psi) | • DN 15 ... 50: 40 bar (/" ... 2": 580 psi) • DN 80: 37.5 bar (3": 540 psi) • DN 100: 30 bar (4": 435 psi) Vacuum: 1 x 10-6 bar (1.5 x 10-5 psi) | |
| | Mechanical load | • 18 ... 1000 Hz random in x, y z, directions for 2 hours according to EN 60068-2-36 • Sensor: 3.17 grms • Sensor with compact MAG 5000/ 6000 mounted transmitter: 3.17 grms • Sensor with compact MAG 6000 I/ 6000 I Ex mounted transmitter: 1.14 grms • For compact installation with the MAG 6000 I, transmitter to be supported to avoid tension on sensor part. | • 18 ... 1000 Hz random in x, y z, directions for 2 hours according to EN 60068-2-36 • Sensor: 3.17 grms | |
| | Enclosure rating • Standard • Option on sensor (no ATEX) | IP67 to EN 60529 (NEMA 4X/6), 1 mH2O for 30 min IP68 to EN 60529 (NEMA 6P), 10 mH2O cont. | IP67 to EN 60529 (NEMA 4X/6), 1 mH2O for 30 min IP68 to EN 60529 (NEMA 6P), 10 mH2O cont. | |
| | EMC | 89/336 EEC | 89/336 EEC | |
| | | | | |