SITRANS F flowmeters
SITRANS F M
Industrial transmitter MAGFLO MAG 6000 I/6000 I Ex d
Technical specifications (continued)
Rated operation conditions
Ambient temperature
• Operation
- MAG 6000 I
-20 ... +60 °C (-4 ... +140 °F)
- MAG 6000 I Ex
-10 ... +60 °C (+14 ... +140 °F)
• Storage
-40 ... +70 °C (-40 ... +158 °F)
Mechanical load
18 ... 1000 Hz random in x, y z,
directions for 2 hours according
to EN 60068-2-36
Transmitter: 1.14 grms
Degree of protection
IP67/NEMA 4X to IEC 529 and
DIN 40050 (1 mH2O 30 min.)
EMC performance
EN 61326
Display and keypad
Totalizer
Two eight-digit counters for for-
ward, net or reverse flow
Display
Background illumination with
alphanumeric text, 3 x 20 charac-
ters to indicate flow rate, totalized
values, settings and faults;
Reverse flow indicated by nega-
tive sign
Keypad
Capacitive touch keypad with
LED light for feedback indication
Time constant
Time constant as current output
time constant
Design
Enclosure material
Die cast aluminium, painted
• Wall mounting
Wall mounting bracket enclosed
for remote version
Dimensional drawings
See dimensional drawings
Weight
See dimensional drawings
• Non Ex d: 18 ... 90 V DC;
115 ... 230 V AC; 50 ... 60 Hz
• Ex d: 18 ... 30 V DC
• Ex d: 115 ... 230 V AC;
50 ... 60 Hz
Power consumption
• 230 VAC: 21.5 VA
•24 V DC: 12 W, IN = 380 mA,
IST = 1 A (3 ms)
Certificates and approvals
MAG 6000 I
• CE
• C-tick
• FM Class 1, div 2
• FM Class 1, Zone 2
• CSA Class 1, div 2
• CSA Class 1, Zone 2
MAG 6000 I Ex (to be used with
• SIRA 03 ATEX 2072X
ATEX 2G D sensors)
• EX II 2 (1) (2) G D
• EEx d e [ia] ia [ib] ib IIC, T6
Cable entries
Remote installation
Communication
Non ATEX versions
ATEX 2G D
HART, MODBUS RTU/RS 485, PROFIBUS PA, PROFIBUS DP add-on modules
HART, PROFIBUS PA available as integrated version
Selection and Ordering data
Order-No.
SITRANS F M Transmitter MAGFLO MAG 6000 I / Ex d
Remote, local display, die cast aluminium
F) 7ME6930-
2
B
A ■■
-
1
Supply voltage
115 ... 230 V AC, 50 ... 60 Hz; 18 ... 90 V DC
ATEX 2G D, 18 ... 30 V DC
ATEX 2G D, 115 ... 230 V AC, 50 ... 60 Hz
Ex approval
None ATEX; FM/CSA class1 div 2
ATEX 2G D
Communication
None (add-on modules can be ordered separately,
see below)
HART
PROFIBUS PA Profile 3
PROFIBUS DP Profile 3 (not Ex version)
MODBUS RTU/RS 485 (not Ex version)
Metric 1/" NPT
4
0
2
A
Industrial communication modules for MAG 60001 (All standard outputs can still be used)
Description
Order No.
Symbol
HART
(only for MAG 6000 I/Ex)
F)
FDK-085U0321
MODBUS RTU/RS485
F)
FDK-085U0234
PROFIBUS PA Profile 3
F)
FDK-085U0236
PROFIBUS DP Profile 3
F)
FDK-085U0237
• MAG 6000 I: 2 x M25(for sup­ply/output) and 2 x M16 (for sen­sor connection) or 2 x V2" NPT (for supply/output) and 2 x M16 (for sensor connection)
• MAG 6000 I Ex ATEX 2G D:
2 x M20 (for supply/output) and 2 x M16 (for sensor connection)
F) Subject to export regulations AL: 9I999, ECCN: N.
4/39
Siemens FI 01 • 2008
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-100
101-150
151-200
201-250
251-300
301-350
351-388
pdf-page pdf di En 2008-10-41-10