SCU Integrated, mini, server room
4Pages

{{requestButtons}}

Catalog excerpts

SCU Integrated, mini, server room - 1

Integrated, mini, server room Overview Genius 6000 integrates rack, power, cooling, and environment monitoring for a complete server room solution. It is a fully integrated, industry-leading plugand-play solution with a ready to use IT rack space. The standard and modular server room architecture dramatically reduces time and complexity from concept and design up to installation. Complete physical infrastructure delivers high availability, efficiency and low Total Cost of Ownership. Fully integrated - complete physical infrastructure, factory assembled and testing Fast deployment - ready to use from one day, simple installation and configuration reduces time to deploy Small foot print - 0.72sqm foot print, suitable for office environment, no need of separate server room Dust protection, noise insulation - fully closed operation, cold/hot air is circulated within the rack, low noise level. Integrated monitor - energy usage monitoring, remote monitoring and automation of your server room Energy saving - inbuilt air-conditioning accurately controls temperature inside the cabinet, small energy consumption

Open the catalog to page 1
SCU Integrated, mini, server room - 2

1. Standard rack cabinet • Standard structure, available space for rack-mounted IT • 4.5KW cooling capacity, Split type: 5U,Integral type: 10U equipment • Totally enclosed design. Noise reduction, sound insulation, dust-proof • Circular air course for cold air from air conditioner, achieving closed heat dissipation • Emergency fans automatically run during power outages • frequency conversion technology, microcomputer temperature control • refrigeration, dehumidification, air supply and dust elimination. • R134 compressor, high performance, industrial fan • Dual safety condensed water...

Open the catalog to page 2
SCU Integrated, mini, server room - 3

5. Power management & PDU • Power management breakers for power, cooling, lighting; inbuilt SPD • PDU: PDU distribute power to IT equipment 6. Environment monitoring • Detect temperature, humidity, access control, water cut and smoke inside the cabinet • Carry out alarm and fault treatment timely 7. Integrated monitoring • User friendly colorful touch screen • Real time monitoring and display of environmental and operation parameters • Alarm management, local alarm, network alarm and self-protection • SNMP V1/V2 protocol; RJ45 interface Traditional Server Room vs. Genius 6000 Room...

Open the catalog to page 3
SCU Integrated, mini, server room - 4

TECHNICAL SPECIFICATION model Dimension (mm) Available space cabinet Server space Area Rated power Backup time Rate voltage Battery Discharge temperature Storage temperature Discharge time Integral type internal circulation air (m3/h) Cooling Split type external circulation air (m /h) Refrigerant outdoor unit noise (dB) indoor unit noise (dB) Temperature sensor Humidity sensor Water leak detection Water Leakage electrode detection Environment monitoring Door access sensor limit switch Integrated monitoring Smoke detection Communication combustible gas, smoke colourful touch screen SNMP...

Open the catalog to page 4

All Sicon Chat Union Electric Co. catalogs and technical brochures

  1. GENIUS 6000

    4 Pages