Catalog excerpts
Operation Manual GoodrivelOO inverter SHENZHEN INVT ELEETRIC ED., LTD.
Open the catalog to page 1GoodrivelQO inverters___Content. 7 1 Bnef instruction to Modbus protocol 85 C 4 Breaker and electromagnetic contactor 105
Open the catalog to page 2GoodrivelOO inverters Safety precautions Please read this manual carefully and follow all safety precautions before moving, installing, operating and servicing the inverter. If ignored, physical injury or death may occur, or damage may occur to the devices If any physical injury or death or damage to the devices occurs for ignoring to the safety precautions in the manual, our company will not be responsible for any damages and we are not legally bound in any manner. Serious physical injury or even death may occur if not follow relèvent Physical injury or damage to the devices may occur if...
Open the catalog to page 3GoodrivelOO inverters Safety precautions -> Please install the inverter on fire-retardant material and keep the inverter away from combustible materials. 4- Connect the braking optional parts according to the wiring diagram. <■ Do not operate on the inverter if there is any damage or components loss to the inverter. __■> Do not touch the inverter with wet items or body, otherwise electric shock may occur. <■ Select appropriate moving and installing tools to ensure a safe and normal running of the inverter and avoid physical injury or death For physical safety, the erector should take some...
Open the catalog to page 4GoodrivelOO inverters Safety precautions Only qualified electricians are allowed to perform the maintenance, inspection, and components replacement of the inverter. Disconnect all power supplies to the inverter before the terminal wiring. Wait for at least the time designated on the inverter after disconnection. Take measures to avoid screws, cables and other conductive matters to fall Into the inverter during maintenance and component replacement._ ■fr Please select proper torque to tighten screws ■C- Keep the inverter, parts and components away from combustible materials during...
Open the catalog to page 5GoodrivelOO inverters Product overview Check as fallowings after receiving producís:_ 1, Check thai there are no damage and humidification to the package. If not, please contact with local agents or INVT offices._ 2. Check the information on the type designation labe! on the outside of the package to verify that the drive is of the correct type. If not, please contact with local dealers or INVT offices._ 3. Check that there are no signs of water in the package and no signs of damage or breach to the inverter. If not, please contact with local dealers or INVT offices._ 4. Check the...
Open the catalog to page 6GoodrivelOO inverters Product overview Check as fallowings after the installation: 1, Check that the load range of the input and output cables meet the need of actual load 2. Check that the accessories of the inverter are correctly and properly installed. The installation cables should meet the needs of every component (including reactors, input filters, output reactors, output filters, DC reactors, braking units and braking resistors)._ 3. Check that the inverter is installed on non-flammable materials and the calorific accessories (reactors and brake resistors) are away from flammable...
Open the catalog to page 7GoodrivelOO inverters Product overview
Open the catalog to page 8GoodrivelOO inverters Product overview The type designation contains information on the inverter. The user can find the type designation on the type designation label attached to the inverter or the simple name plate. Below is the layout figure of the inverter (take the Inverter of 2.2kWas the example).
Open the catalog to page 9GoodrivelOO inverters Product overview
Open the catalog to page 10GoodrivelOO inverters Installation guidelines The chapter describes the mechanical installation and electric installation. ■t- Only qualified electricians are allowed to carry out what described in this chapter. Please operate as the instructions In Safety Precautions Ignoring these may cause physical injury or death or damage to the devices. Ensure the power supply of the inverter is disconnected during the operation. Wait for at least the time designated until the POWER indicator is off after the disconnection if the power supply is applied. It is recommended to use the multimeter to...
Open the catalog to page 11GoodrivelOO inverters Installation guidelines ♦ GoodrivelOO series inverters should be installed in a clean and ventilated environment according ♦ Cooling air must be clean, free from corrosive materials and electrically conductive dust. The inverter may be installed on the wall or in a cabinet. The Inverter must be installed in an upright position. Check the installation site according to the requirements below. Refer to chapter Dimension Drawings in the appendix for frame details, The Inverter can be installed in two different ways, depending on the frame size: a) Wall mounting (for all...
Open the catalog to page 12GoodrivelOO inverters 3.2.1 Connection diagram of main circuit Installation guidelines Fig 4-4 terminals of main circuit ♦ Do not use an asymmetrically constructed motor cable. If there is a symmetrically constructed grounding conductor in the motor cable in addition to the conductive shield, connect the grounding conductor to the grounding terminal at the inverter and motor ends. ♦ Route the motor cable, input power cable and control cables separately.
Open the catalog to page 13GoodrivelOO inverters Installation guidelines 3.2.3 Wiring of terminals in main circuit 1. Fasten the grounding conductor of the input power cable with the grounding terminal of the inverter (PE) by 360 degree grounding technique. Connect the phase conductors to R, S and T terminals and fasten. 2. Strip the motor cable and connect the shield to the grounding terminal of the inverter by 360 degree grounding technique. Connect the phase conductors to U, V and W terminals and fasten. 3. Connect the optional brake resistor with a shielded cable to the designated position by the same procedures...
Open the catalog to page 14GoodrivelOO inverters Installation guidelines
Open the catalog to page 15GoodrivelOO inverters Installation guidelines 3.2.6 Input /Output signal connection figure Please use U-shaped contact tag to set NPN mode or PNP mode and the internal or external power supply. The default setting is NPN internal mode. If the s;gnal is from NPN transistor, please set the U-shaped contact tag between +24V and PW as below according to the used power supply. If the signal is from PNP transistor, please set the U-shaped contact tag as below according to the used power supply. 3.3.1 Protecting the inverter and input power cable in short-circuit situations Protect the inverter...
Open the catalog to page 16All ShenZhen INVT Electric Co. catalogs and technical brochures
-
Goodrive20-LA series
10 Pages
-
Goodrive20/Goodrive310 Series
16 Pages
-
Goodrive20 Series
10 Pages
-
GD170-PV Series
6 Pages
-
GD27 Series Smart VFDs
15 Pages
-
HMI Product Catalog
8 Pages
-
STICK LOGGER
2 Pages
-
XG50-70kW
1 Pages
-
Goodrive300 Series VFD
292 Pages
-
Goodrive200A series
11 Pages
-
AX Series
21 Pages
-
Solar Pumping Controller
6 Pages
-
MH800 Hydraulic Servo System
24 Pages
-
Products catalogue
15 Pages
-
EMI power filter
8 Pages
-
About INVT
2 Pages
-
INVT Album
2 Pages
-
INVT products catalogue
12 Pages