video corpo

INVT CHE100 Series Sensorless Vector Control Inverter
2Pages

{{requestButtons}}

Catalog excerpts

INVT CHE100 Series Sensorless Vector Control Inverter - 1

CHE100?? table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:20.00pt "Arial", sans-serif; } .font1 { font:8.00pt "Franklin Gothic Medium", sans-serif; } .font2 { font:9.00pt "Franklin Gothic Medium", sans-serif; } .font3 { font:14.00pt "Franklin Gothic Medium", sans-serif; } CHE100 Sries SENSORLESS VECTOR CONTROL FREQUENCY INVERTER Technical Features i/o features Power range Input Frequency Range Output Voltage Range Output Frequency Range input terminais 3 AC 380-4S0V±15% 0.75KW-11KW 47~63Hz 0~rated input voltage 0~400Hz Programmable DI: 4 Programmable At Ail: 0-10V, AI2:0-10V or 0-20mA output terminais communication terminais control mode Speed Adjusting Range Overload Capacity Frequency rf驩rence source Programmable Open Collector Output: 1 (open collector or high speed puise output selectable) Relay output 1 Analog output: 1 (AOl: 0/4-20mA or 0-lOV) Provide RS485 communication interface, adopt Modbus-RTU communication mode V/F control, sensorless vector control (SVC) 1:100{SVQ 60s with 150% rated current 10s with 180% rated current Keypad,Analoginput,Serialcommunication1Multi-stepspeed1 PIDandsoon.Thecombinationofmulti-modesandswitchingbetweendifferentmodescanberealized ♦ Traverse Control Function ♦ PID Control Function ♦ Carrier frequency: 0.5kHz-15.0kHz ♦Starting torque: 150% of rated torque at 0.5Hz(SVC) ♦Speed accuracy: ±0.5% of maximum speed(SVC) ♦ Multi-step speed control function: 8 steps speed can be set ♦ None-stop when instantaneous poweroff ♦ Speed trace function: start the motor smoothly ♦ Automatic voltage rgulation function ♦ Up to 24 fault protection: over current over voltage, under voltage, over temprature, phase failure, over load etc. Can display: setting frequency, output frequency, output voltage, output current etc. The QUICK/JOG key-press can be used as multi-function key-press. if the installing and wiring of the inverter together with the EMI filter according to (Manual of CHF100A) , we can promise it's must meet the following criterion: Contrai function other functions Man-Machine LED display Interface multi-function key-press EMC EMC criterion I EN61000-6-4 I EN61800-3 [Normally, if the cable of motor is longer than 50m, it's should install AC reactor or sinuso驯dal filter at the output side of the inverter] -10°C ~ +40°C Inverter will be derated if ambient temprature exceeds 40°C. <90%, without condensation temprature humidity altitude S1000M, output rated power >1000M, output power with derating The inverter is prohibited to drop on the floor or with suddenly impact it also prohibited to be installed at the place where the oscillation may occur very probably. The inverter is prohibited to be installed at the place where stronger electromagnetic radiation may occur very probably. The inverter is prohibited to be stored at the place where with direct sunlight fall of oil mist steam and with heavy oscillation. environmental constraint impingement and oscillation electromagnetic radiation store environ ment web site: www. i nvt.com

Open the catalog to page 1

All ShenZhen INVT Electric Co. catalogs and technical brochures

  1. STICK LOGGER

    2 Pages

  2. XG50-70kW

    1 Pages

  3. AX Series

    21 Pages

  4. About INVT

    2 Pages

  5. INVT Album

    2 Pages