Text version of the page
Text version of the page
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Applications | | | | | | | | | | With its high precision and wide temperature range (-120 to 830 °C) the SENSYS evo TG-DSC has a wide range of applications, especially in the fields of thermodynamics (Specific Heat Capacity Cp precision within %), pharmaceuticals (phase diagram, polymorphism, purity, thermal stability), safety of chemical process (transition, decomposition under high pressure), energy (catalysis, hydrogen storage, hydrogen adsorption), polymers (glass transition, measurement under pressure), etc. View the application notes in your field, available for download, by visiting www.setaram.com! A huge database is in the Application Library area of our website. We have also included a powerful search engine that will enable you to find the most applicable data. | | | | | | | | | | Specifications | | | | | | | | | | | | | | | | | Temperature range | Ambient to 830 °C | | | | With cooling accessories | -120 °C to 200 °C (Liquid Nitrogen Accessory) | | | | Temperature accuracy | +/-0.1 °C | | | | Temperature precision | +/-0.02 °C | | | | Programmable temperature scanning rate (heating and cooling) | 0.01 to 30 °C min-1 | | | | Cooling time | 17 min (from 50 °C to -100 °C) with Liquid Nitrogen Accessory | | | | DSC | | | | | Enthalpy accuracy | % | | | | Calorimetric Precision | +/-0.1 % | | | | RMS Noise | 0.2 uW | | | | Sensitivity (Joule effect at 30°C) | 6.7 uV/mW | | | | Resolution | 0.35 uW / 0.035 uW | | | | Dynamic range Resolution | +/-2500 mW | | | | Gases | 3 carrier gases (MFC from 4 to 200 ml/min) + 1 auxiliary or reactive gas (MFC from 0.3 to 16 ml/min)* | | | | Crucibles | 120 ul, 160 ul, 320 ul aluminium, incoloy, gold plated incoloy, graphite, alumina, platinum, etc. | | | | Pressure (non controlled) | High Pressure Crucible (up to 500 bars / 7250 psi at 600 °C) | | | | Pressure (measured & controlled) | High Pressure Crucible (up to 400 bars / 5800 psi at 600 °C) | | | | TG | | | | | Maximum balance capacity | 3 g | | | | Weight range | +/-200 mg | | | | Weighing precision | +/-0.01 % | | | | TG Resolution | 0.02 ug, 0.002 ug | | | | Baseline dynamic drift | < 10 ug | | | | Isothermal temperature accuracy | +/-0.1 °C | | | | Linear heating rate | 30 °C/min | | | | Vacuum | < 10-1 mbar | | | | Evolved gas | MS, FTIR, GC couplings | | | | Weight | 55 kg (121 lbs) | | | | Dimensions (Height / Width / Depth) | 60 closed, 80 opened / 53 / 58 cm (23,6 closed, 31.4 opened / 20.9 / 22.8 in) | | | | k Power requirements | 230 V - 50/60 Hz J | | | | | | | | | | | | | ê g c o 0 | | | | | | | | | | o j_ | | | | | | | | | | cd 2 | | | | | | | | | | 3 j_ 2 | | | | | | | | | | | | | | Option: AKTS Thermokinetics software for decomposition ^WkE | | comprehensive investigation of reaction or | | | | | | | | | | SETARAM INSTRUMENTATION 7 rue de l'Oratoire 69300 Caluire - France Phone +33(0)4 72 10 25 25 Fax +33(0)4 78 28 63 55 SETARAM Inc. (NJ office) 7905 Browning Rd, Suite 206 Pennsauken NJ 08 109-4323 - USA Phone +1 (856) 910 9990 Fax +1 (856) 910 1150 SETARAM Inc. (HQ) 8430 Central Ave. Suite 3D Newark, CA 94560 - USA Phone +1 (510) 793 3345 Fax +1 (510) 402 4705 | | | | | | | | | | b&TARAM IméK^ZI Instrumentation | | | | | | | | | | Tech | | o I o Q I e s» | | | | | | | | | | | | | | Offices in United Kingdom, Germany, Italy, Switzerland, China and Singapore www.setaram.com sales@setaram.com | | | | | | | | | | | | | | Inspiring Imagination for Material Science | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|