SETSYS Evolution TG-A-DTA/DSC

• SETSYS Evolution TGA-DTA: couple DTA to your balance... The thermogravimetric method only indicatesthe variation in mass of the sample. By coupling DTA to thermogravimetric measurement, the corresponding thermal effect is combined and measured. DTA moreover detects transformations in the sample (fusion, crystallization, transition) that are not associated with variations in mass. To optimize its range of SETSYS Evolution TGA thermobalances, SETARAM has developed a fitting for hanging the DTA transducer on to the weighing module so as to take simultaneous TGA and DTA measurements on the same sample.With a single structure the thermobalance can thus be used in thermogravimetry alone (SETSYS Evolution TGA model)or in simultaneous TGA-DTA mode (SETSYS Evolution TGA-DTA model). Changing from one mode to the other is quickand easy.

The simultaneous TGA and DTA/DSC measurements

• SETSYS Evolution TGA-DSC : couple DSC to your balance In the same way, it is possible to couple a DSC rod to the balance and thus to obtain simultaneously the measurement of the TGA and the DSC signals, which will give quantitative information on the thermal exchanges. • SETSYS Evolution TGA-DTA 24… very high temperatures at a reasonable price The SETSYS Evolution TGA-DTA 24 results from developments made by SETARAM on the SETSYS series with thegraphite-resistor industrial furnace. At present, a compact, sturdy and easy-to-use table thermobalance provides for simultaneous TGA-DTA measurements in inert gas (argon) up to 2400°C. • Four transducers from -150°C to 2400°C The thermal transducers used on the SETSYS Evolution TGADTA models are identical to those on the SETSYS Evolution DTA models: - the tricouple transducer - the monocouple, protected transducer- the DSC-type, plate transducerThese three transducers are made of platinel (1000°C), Pt/Pt-Rh 10 % (1600°C), Pt-Rh 6 % /Pt-Rh 30%(1750°C)- the very high temperature plate transducer in tungsten-rhenium for simultaneous TGA-DTA measurements upto 2400°C.
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
pdf-page pdf di En 2009-01-02-09