2.1.2 General information
Influence of humidity on L10 and MTBF
SEPA® DC industrial fans are equipped with protected industrial ball bearings (Type ZZ) and electronics protected by a labyrinth against the direct effect of humidity so that its influence on service life and reliability is minimized.
The standard information described in the specifications always refers to a mean humidity of 15-65% RH, uncritical test values to 15-75% RH. This information determines the environmental conditions defined for testing so that their influence is minimised as far as possible.
The limit values permitted when in use are limited at the lower end by the increase of possible ESD interference and at the top end by the development of drops of condensation. A fan installed in a device is normally completely insensitive to ESD interference. At the upper end, only the formation of condensation needs preventing. Due to the insignificant heating of the fan during operation, condensation cannot form even when humidity is almost 100%.
As mentioned above, the permitted humidity range during operation can be defined at 10-98% RH, if there is no possibility of condensation forming.
Conditions are different if the fan is taken from a cold to a warm room, e.g. when transporting devices from a non-heated storeroom to a heated room. Under certain conditions, slight humidity may cause the formation of condensation, however the drops will form mainly on the outside of the housing.
The fan frame and housing are absolutely waterproof. A temporary formation of condensation that seldom occurs will not negatively affect the performance of the fan.
Slow changes in temperature in the area of operation of the fan will not have an affect as long as the fan and surrounding air have approximately the same temperature. This also applies to high humidity of approx. 98% RH, without formation of mist.
If mist is formed continuously due to high humidity, this can reduce the service life of fans, in particular when the steam contains aggressive media (e.g. acids). This is also possible if the fan never runs or only seldom runs.
Mechanical industrial filters do not provide additional protection against excess humidity and the formation of mist.
SEPA EUROPE GmbH • D-79108 Freiburg • Tel.: +49/761/3842273-0 • Fax: +49/761/3842273-99
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-100
101-115
pdf-page pdf di En 2009-01-02-09