semtech® LAMBDAMASTER ON-BOARD, IN-USE AIR FUEL RATIO ANALYZER - Sensors Europe - #1 |
|
You may also be interested in
NDIR analyzer, Hand-held analyzer, Analyzer, Flow-meter, Laboratory diluter
Text version of the page
Last Revision 09/08
Product Specifications:
MEASUREMENTS RANGE 7-100 AFR
ACCURACY ± 0.04% volume of O2
STABILITY Better than ± 0.02% volume O2 over 2 hour measurement period
RESOLUTION ± 0.01% volume O2
REPEATABILITY Better than ± 0.02% volume O2. Typically equivalent to better than ±
0.05 AFR, ± 0.003ë (Over range 7-100 AFR)
RESPONSE RISE TIME Air to Nitrogen; 90% change in less than 100 milliseconds.
EXHAUST SAMPLE FLOW Approximately 5 liters per minute
WARM UP TIME 60 minutes
TYPICAL CATALYST LIFE 500 hours unleaded fuel, 50 hours leaded fuel
OPERATING TEMPERATURE 0 to 50ºC
RECORDER OUTPUTS (STANDARD) 0 to 1V : 0 to full scale for ë/AFR/O2 ; 0 to 1V : 0 to 10% O2
HC RATIO ADJUSTMENT RANGE 0.00 to 4.00
OC RATIO ADJUSTMENT RANGE 0.00 to 1.00
HEATED SAMPLE LINES 3 meters length standard, 1, 5, 8 or 10 meters options directly
interchangeable
CONNECTING CABLE - CONTROL UNIT TO 17 way x 6 meter long. 1 to 25 meters; Optional
SAMPLE HANDLING UNIT
SAMPLE FILTER 19 mm x 90 mm Whatman extraction thimble
ELECTRICAL POWER REQUIREMENTS Electronics Module: <200W + 12V DC Cart: 1KW
DIMENSIONS (IN; W x H x D) Control Unit : 10.5 x 6.5 x 3.5
Transducer : 13.5 x 3.0 x 3.0
WEIGHT Control Unit : 6.50 lbs
Transducer : 4.25 lbs
ON-BOARD, IN-USE AIR FUEL RATIO ANALYZER
SEMTECH® LAMBDAMASTER
semtech
LAMBDAMASTER
ON-BOARD, IN-USE AIR
Note: Specifications are subject to change without notice. While due caution has been exercised in the production of this
document, errors and omissions can occur.
Sensors, Inc. 6812 State Road Saline, Michigan USA +1 (734) 429 – 2100 www.sensors-inc.com
Sensors Europe GmbH Feldheider Str. 60 40699 Erkrath Germany +49-(0)2104-14188-88
Sensors, Inc. 6812 State
Sensors Europe GmbH
|
|