| | | Self-Generating vibration transducer, 20mV/mm/s output, +200°C operation and broadband velocity performance 4.5Hz - 2KHz. The VEL-G series of Vibration Transducers are robust, sealed instruments suitable for operation in heavy industrial environments. This self-generating transducer produces a signal proportional to the velocity component of a mechanical vibration by means of relative movement between a coil and a magnet.The signal level is suitable for direct connection to most signal conditioning and data recording equipment. The main body of the transducer is fitted with a polished stainless steel case and contains a moving coil and magnet assembly. The coil is suspended within the field of the magnet by means of diaphragms, which permit virtually frictionless movement in one axis only. This measuring axis is coincident with the axis of the cylindrical body. | | |
| | | |
| | | Application • Heavy Industrial • Large Motors • Self-Generating • High Temperature | | Interface Options • Integral PTFE Cable • Armoured • MIL 2-pin Conn • Isolated Conduit • Top or side exit | | |
| | | |
| | | Specifications • Output Sensitivity: 4mV/mm/s or 20mV/mm/s in to lOkOhm Load • Accuracy: ±3% • Linearity : ±3% at 100Hz • Max Displacement: ±2.5mm • Output Impedance : 200Ohm nom. • Max Acceleration : 2000g sensitive axis; 50g non-sensitive axis • Temperature Range: -40°C - I00°C; 200°C extended range available. | | |
| | | vra*. i m mimici mum od | | |
| | | |
| | | 1 | | |
| | | |
| | | |
| | | '';-;cu«*-_ no _ Dimensions (shown with primary axis vertical - 0° reference) | | |
| | | • Mass: 480 grams | | |
| | | |
| | | |
| | | | | | | | | | | | | Freq. Range (Hz) | Angle of Calibration | Angular Range of Operation (Degrees) From Angle of Calibration | Max. Sensitivity Dev • | Option | | | | 15-2000 | Vertical 0° | Universal (vertical 0° +/- 180°) | -10% | 1 | | | | 10-2000 | Vertical 0° | Universal (vertical 00 +/- 180°) | -12% | 2 | | | | 10-2000 | Horizontal 90° | Horizontal (90° +/-10°) | +/- 2% | 3 | | | | 4.5-2000 | Horizontal 90° | Horizontal (90° +/-20°) | - 20% | 4 | | | | 4 5 - 2000 | | 45° +/- 20° | -10% | 5 | | | | 4.5 - 2000 | Vertical 0° | Vertical (0° +/- 20°) | -6% | 6 | | | | | | | | | | | | |
| | | |
| | | Output sensitivity deviation over frequency range versus mounting angle relative to angle of calibration | | |
| | | |
| | | Model No. Config VELG -9 (self generating) VELGT (200'C) | | Connection Exit 6C (Cable unarmoured) T (top) 6D (Cable armour) S (side) 8E (Integral Conn 2-pin) 8F (Integral Conn 3-pin) 9C (Conduit - see below) | | Cable Length Sensitivity Mounting Specify in metres i 4mV/mm/s i ('/«" UNF) e.g. 05 (5m) 2 20mV/mm/s 2 ('/," UNF) max 25m 3 (M8) 4 (2 hole plate) Configuration - select from table above 1-6 | | |
| | | |
| | | |
| | | |
| | | e.g. VELG-9-6DT-03-2I2 :- VELG model, 2-wire, 3m armoured cable top exit, lOmV/mm/s, V." UNF, Universal operation, 10Hz to 2/<Hz. | | |
| | | |
| | | Conduit Fitting 0 (None) 1 (%" BSP) 2 (MI6 Male) 3 (M20 Male) | | |
| | | For armoured flexible conduit options select 9C and specify type and fitting e.g 9C0I (non-isolated with %" BSP fitting) Conduit length is 0.5m less than cable length | | Conduit 0 (non-isolated) 1 (Isolated) | | |
| | | |
| | | |
| | | |
| | | 10 | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |