2 x accelerometer. 100mV/g sensitivity as standard (or 1 x accelerometer and 1 x temperature sensor) (Option for velocity transducer input available) Other DIN rail monitors in the range can monitor shaft vibration, temperature, thrust, position (LVDT), speed, reverse rotation 24V dc (22-28V dc) Factory set to monitor acceleration or velocity 3 digit LCD display switchable between channels and alarm setpoints. Display in engineering units (mm/s or Inch/s) 2 x 4-20mA proportional to vibration level (1 per channel) Full scale of current outputs are selectable on site, from a standard list by the positioning of onboard switches Buffered raw transducer signal available on BNC connector for analysis purposes 2 x individually adjustable level alarms (2 per channel) Relays: 2 relays common to both channels. 1 for Alert (A1) and 1 for Danger (A2) High and low pass filters are selectable on site, from a standard list, by the positioning of onboard switches Doe lo our continuous improvement policy, specifications may change without notice. |