| Input: 2 x accelerometer. 100mV/g sensitivity as standard (or 1 x accelerometer and 1 x temperature sensor) (Option for velocity transducer input available) Other DIN rail monitors in the range can monitor shaft vibration. temperature, thrust, position (LVDT), speed, reverse rotation Power: 24V dc (22-28V dc) Mode: Factory set to monitor acceleration or velocity Display: 3 digit LCD display switchable between channels and alarm setpoints. Display In engineering units (minis or Inch/s) Outputs: 2 x 4-20mA proportional to vibration level (1 per channel) Scaling: Full scale ot cunent outputs are selectable on site, from a standard list by the positioning of onboard switches Signal: Buffered raw transducer signal available on BNC connector for analysis purposes Alarms: 2 x individually adjustable level alarms (2 per channel) Relays: 2 relays common to both channels. 1 for Alert (A1) and 1 for Danger (A2) Filters: High and low pass filters are selectable on site, from a standard list, by the positioning of onboard switches Fax: +44(0)1442 876 477 E-mail: sales@sensonics.co.ul Website: www.sensonics.net |