10 pages in the catalogue
SDP1000 / SDP2000 Differential Pressure Sensor |
![]() |
SDP1000 / SDP2000 Differential Pressure Sensor p 1 SDP1000 / SDP2000 Low Range Differential Pressure Sensor for Air and Non-Aggressive Gases For cost sensitive HVAC and medical OEM applications Unsurpassed performance thanks to CMOSens ® technology O... |
![]() |
SDP1000 / SDP2000 Differential Pressure Sensor p 2 1 Specifications Table 1: Sensor specifications (at 23°C and p absolute = 966 mbar, VDD = 5.0 V unless otherwise noted). SDP1000-L05 SDP1000-L SDP1000-R SDP2000-L SDP2000-R Unit Parameter Min Typ Max... |
![]() |
SDP1000 / SDP2000 Differential Pressure Sensor p 3 Table 2: Additional sensor specifications. Media Air, N 2 – for other gases contact Sensirion AG. Operating Conditions: - Temperature - Humidity -10 °C … +60 °C / 14°F … 140 °F no... |
![]() |
SDP1000 / SDP2000 Differential Pressure Sensor p 4 SGNSIRION THE SENSOR COM PAM Y 2 Electrical Specifications 2.1 Power Supply The SDP1000 / SDP2000 differential pressure sensors require a stable voltage supply of 5 V. Influence of the supply voltage... |
![]() |
SDP1000 / SDP2000 Differential Pressure Sensor p 5 Table 4: SDP1000 / SDP2000 electrical characteristics. Parameter Conditions Min. Typ. Max. Units Power Supply Voltage V DD 4.75 5.0 5.25 VDC Operating Current 5 V, no load 3 5 mA Output capacitive lo... |