CMOSens® EM1 Mass flow meter for Gases
THE SÊMSOR COMPANY
For the above reasons, Sensirion guarantees the industrial safe use of the CMOSens® EM1 Mass Flow meter manufacturer for inert, in-explosive and non-toxic gases only.
temperature mode. An explanation of the overflow modes can be found in section 1.1.
I received value (hex)
received value (dec)
flow [ln/min ]
temperature
ra
0x7852
30802
overflow
~
0x7851
30801
peak overflow
~
0x7850
30800
+240.600
+308.00*
0x0001
1
+0.007813
0.01
0x0000
0
0.000000
0.00
0xFFFF
-1
-0.007813
-0.01
0x87B0
-30800
-240.600
-308.00*
Pins and Electrical Interfaces
2
TiD
ISS
^>
RiD
SCK
MISO
=
MOSI
'-
ICS
wo
Figure 5: CMOSens® EM1 pin out.
The electrical connector on the cover of the CMOSens® EM1 is a Molex PN 53014-0810 (straight header, male, 8Pin). You need a Molex PN 51004-0800 connector housing (female, 8 Pin) with crimp contacts Molex PN 50011-8100 to connect the sensor. Please check the Molex homepage for details (http://www.molex.com).
2.2 Power supply
The CMOSens® EM1 Mass Flow Meter requires a voltage supply between 7V and 18 V. Since this voltage is internally regulated, there are no stringent requirements as far as ripple and stability are concerned.
2.3 Digital Interface
The CMOSens® EM1 Mass Flow Meter has two interfaces: One is a bi-directional RS232 to set configuration and to get flow or temperature values. The other one is a uni-directional SPI that only sends flow or temperature depending on the configuration which was made by RS232.
2.4 Dataformat and Interpretation
The received value is a 16 bit signed integer in the two's complement representation. The calibrated data is multiplied by a constant factor and then rounded to the next smaller integer in order to transfer also fractions of an unit through the integer protocol. This factor for flow is 128 for the EM1NV, 1 for the EM1NR and 50 for the EM1NL version. For the temperature for all versions the factor is 100. Example: a received value of +1234 (dec) corresponds either to 9.641 ln/min in flow mode or 12.34 °C in
*not possible value, just to show the principle Figure 6: Interpretation of Integervalues 2.5 RS232 Interface
All configurations (see also Section 3) for the CMOSens® EM1 can be set using its RS232 interface. The following pins are required to communicate with the CMOSens® MFM via RS232:
RxD (Receiving Data Line) TxD (Transmitting Data Line) GND (Ground)
The RS232 protocol of the CMOSens® MFM is configured as follows:
Baudrate 19200
Data Bits 8
Stop Bits 1
Parity none
Protocol none
Echo the sensor generates an echo
With these settings, the CMOSens® EM1 device can be connected to any PC or device with an RS232 interface. The commands have to be sent in ASCII format, the measurement values are provided as a 16 bit signed integer in binary format with 2 bytes synchronization preceding.
www.senslrlon.com
Data Sheet EM1 -v2.5/ August 2006
7/16
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
pdf-page pdf di En 2009-01-02-09