K-LINE Compact converters 6,2 mm normalized case TECHNICALFEATURES

GENERALINFORMATIONS DIMENSIONS

K109PT K109PT1000 K109TC K109UI K109S K109SH K107A K107B K107USB K-SUPPLY

Power supply range*Industrial bridge voltage supply 19,2.. 30 VdcBus connectors (K-BUS) can be snapped onto 35 mm DIN guide rail according to EN 60175 Wire section 0,2..2,5 mm
2
Wire stripping 8 mm Power on side terminals Yes Hot swapping Yes Max current consumption 21..25 mA(24 Vdc) Consumption without load at 25°C 7,5 mA
Pt100 industrial converter Pt1000 converter Thermocouple converter withsettable threshold Galvanic isolator analogue converter V / I converter with active output Current shunt / V-I converter RS485/RS485 serial repeater RS232/RS485 serial converter RS485/USB asyncronous serial converter K-BUS power supply for K-line modules
Max power consumption 500 mOhm A/D conversion 14 bit
3 way galvanic isolator conver-ting Pt100 temperature in stan- dard current/voltage signal. 3 way galvanic isolator conver-ting Pt1000 temperature in standard current/voltagesignal. 3 way galvanic isolator for ther-mocouple input. Settable acti- ve output, auxiliary switchingrelay output, exceeding threl-hold. 3 way galvanic isolator for cur-rent or voltage conversion. Passive input and active out-put. 3 way galvanic isolator for vol-tage or current conversion. Active output and floatingpower supply. 3 way galvanic isolator for the con-version of a current shunt value into a current or voltage signal.Programmable scales. RS485 serial repeater, 3 ways isolation, automatic flow control. RS232B / RS485 serial converter, halfduplex, , 3 ways isolation, automatic flow control. RS485/USB serial converter withspecific drivers. Isolated RS485 / USB interface. Redundant power supply modulewith overvoltages protection and dif- ferential mode filter.
Rejection 50 o 60 Hz (programmable) Settings DIPSwitch Filter Insertable Dimensions 93,1 x 6,2 x 102,5 mm Isolation 1,5 KV (50 Hz, 1 min)

GENERALDATA

Isolation technique Digital (optocoupler) Processing Floating point 32 bit
Channels 1 input, 1 output 1 input, 1 output 1 input, 2 outputs 1 input, 1 output 1 input, 1 output 1 input, 1 output 1 input, 1 output 1 input, 1 output 1 input, 1 output 2 inputs, 1 output
Colour Black
Precision 0,1 % 0,1 % 0,1 % 0,1 % 0,1 % 0,1 %
Case material PBT
Thermal driftLED < 100 ppm/K • Fault / alarm < 120 ppm/K• Fault / alarm < 120 ppm/K• Fault / alarm • Threshold setting • Static relay output status < 120 ppm/K• Fault / alarm < 120 ppm/K• Fault / alarm < 120 ppm/K• Fault / alarm
Weight 45 g
• Power ON• Data OK• Inverted connection • Power ON• Data OK• Inverted connection • Power ON• RS485 Rx• RS485 Tx • Input 1 switch on threshold • Input 1 switch on threshold • Alternate / inverted polarity of inputs
Operating temperature -20..+65 °C Storage temperature -40..+85 °C Humidity 10..90 % non condensing Connection Clamp terminals and/or bus
Power supply • 19,2..30 Vdc • 19,2..30 Vdc • 19,2..30 Vdc • 19,2..30 Vdc • 19,2..30 Vdc • 19,2..30 Vdc • 19,2..30 Vdc • 19,2..30 Vdc • By USB port of the PC
Protection degreeConformity IP20CE, EN 50081-2, EN 50082-2, EN 61010-1, EN
Isolation • 1,5 kV (50 Hz, 1 min) • 1,5 kV (50 Hz, 1 min) 1,5 kV (50 Hz, 1 min) • 1,5 kV (50 Hz, 1 min) • 1,5 kV (50 Hz, 1 min) • 1,5 kV (50 Hz, 1 min) • 1,5 kV (50 Hz, 1 min) • 1,5 kV (50 Hz, 1 min) • 1.500 V (USB / RS485) Dimensions Communication • 93,1 x 6,2 x 102,5 mm • 93,1 x 6,2 x 102,5 mm • 93,1 x 6,2 x 102,5 mm • 93,1 x 6,2 x 102,5 mm • 93,1 x 6,2 x 102,5 mm • 93,1 x 6,2 x 102,5 mm • 93,1 x 6,2 x 102,5 mm• Timing automatic handshake• Baud rate: 1.200..115.200 bps • Terminal • Flow communication stop • 93,1 x 6,2 x 102,5 mm• Timing automatic handshake• Baud rate: 1.200..115.200 bps • Terminal • Flow communication stop • 93,1 x 6,2 x 102,5 mm• Baud rate: 1.200..250 kbps• RS485 line terminal • 93,1 x 6,2 x 102,5 mm
60742
* Except for K107USB and K-SUPPLY

CONNECTION AND INSTALLING

Special functions • Programmable fault and cut-off • Insertable filter • Programmable fault and cut-off • Insertable filter • Programmable fault and cut-off • Insertable filter • Settable rejection 50 – 60 Hz • Square root extraction • Standard industrial tanks linearisation• Signal inversion • Programmable cut-off • Programmable scales on demand • Square root extraction • Standard tanks linearisation• Signal inversion • Programmable cut-off • Auxiliary power supply on 3 terminal • Compliance to USB 1.1 and 2.0• Plug&play for WIN 98, 2000 and XP• Multiple connection on the same PC • CD Driver • Differential mode filter• Integrated protection against overvoltages • Connection with redundant power supply, to several bus and parallel inputs

CAGE CLAMPCONNECTION K-BUS

Instruction sequenzerequires stripping of cables, opening block spring with a screwdri- ver, inserting the cable in the hole. Module is screw holdon the top of DIN guide, then it has to pressed to the bottom for the final clip-on fastening. Each expandable con-nector K-BUS allows inserting two modules. K-BUS are inserted on guide setting them to the top and round them at the bottom.

blocks 17..20 V, max current 25 mA

INPUT DATA

Type PT100 • Pt100 (IEC 751 / EN 60751 – ITS90) • Range: -150..+150 °C • Minimum span: 50 °C• Power on transmitter 900 ΅A• Connection technique: 2, 3, 4 wires • Max conductor resistance: 20 Ω PT1000 • Pt1000 (EN 60751/A2 - ITS90) • Range: -200..+210 °C • Minimum span: 30°C• Power on transmitter < 350 ΅A• Connection technique: 2, 3, 4 wires • Max conductor resistance 50 Ω THERMOCOUPLE • Type: J, K, E, N, S, R, B, T(ITS-90 standard)• Temperature range: minimum span 100°C• Impedance: 10 M Ω • VOLTAGE • Range: 0..10 / 2..10 / 0..5 / 1..5 / 0..15 / 0..30 V reversed• Impedance: 110 k Ω(10 V), 325 k Ω(30 V) VOLTAGE • Range: 0..10 / 10..0 / 0..5 / 1..5 V • Impedance: 110 kΩ CURRENT VOLTAGE SERIAL • Half duplex (31 nodes, teminal, protection up to 30 Vdc) SERIAL • RS232B, protection up to 30 Vdc SERIAL • USB interface, USB standard 1.0 / 2.0 compliance, USB Aand MINI USB B connectors POWER SUPPLY • 2 inputs with shared negative terminal • Pass-through each input can be accessed by 2 pairs of terminals • Max current per terminal: 4 A• Positive inputs protected by an external industrial fuse of recommended sizing • Range: 0..20 / 4..20 mA• Impedance: 35 Ω • Shunt: from ±100 mV up to ±500 mV • Range: 0..20 / 4..20 mA • Impedance: 35 Ω CURRENT Cold junction (semiconductor, ADC 13 bit, precision 1,4 °C, time upgrade 10s) Absolute value • Max voltage ±32 V • Max voltage:±32 V • Current clamp self powered: 400 mΩ • Max voltage:±30 V • Current clamp self powered: 400 mΩ

OUTPUT DATA

Type VOLTAGE • Range: 0..10 / 10..0 / 0..5 / 1..5 V • Max voltage: overrange 10,25 V; fault 10,5 V, available 12 V• Min load resistance: 2 k Ω VOLTAGE • Range: 0..10 / 10..0 / 0..5 / 1..5 V • Max voltage: overrange 10,25 V; fault 10,5 V, available 12 V• Min load resistance: 2 kΩ VOLTAGE • Range: 0..10 / 10..0 / 0..5 / 1..5 V • Min load resistance: 2 kΩ VOLTAGE • Range: 0..10 / 2..10 / 0..5 / 1..5 V • Min load resistance: 2 kΩ VOLTAGE • Range: 0..10 / 2..10 / 0..5 / 1..5 V • Min load resistance: 2 kΩ TENSIONE • Range: 0..10 / 2..10 / 0..5 / 1..5 V • Min load resistance: 2 kΩ SERIAL • RS485 Half duplex (31 nodes, teminal, protection up to 30 Vdc) SERIAL • RS485 Half duplex (31 nodes, terminal, protection up to 30 Vdc) SERIAL • RS 485, max 31 nodes, spring-cage terminal block POWER SUPPLY • Max voltage drop: 300 mV

INSERTING MODULE ON DIN GUIDE EXTRACTING MODULE ON DIN GUIDE

• Range: 4..20 / 20..4 / 0..20 / 20..0 mA• Max current: overrange 20,5 mA; fault 21 mA, protection 25 mA• Max load resistance: 500 Ω • Range: 4..20 / 20..4 / 0..20 / 20..0 mA• Max current: overrange 20,5 mA; fault 21 mA, protection 25 mA• Max load resistance: 500 Ω CURRENT CURRENT CURRENT CURRENT CURRENT CURRENT • Range: 4..20 / 20..4 / 0..20 / 20..0 mA• Max load resistance: 500 Ω • Range: 4..20 / 20..4 / 0..20 / 20..0 mA• Max load resistance: 500 Ω • Protection: 25 mA • Range: 4..20 / 20..4 / 0..20 / 20..0 mA• Max load resistance: 500 Ω • Protection: 25 mA • Range: 4..20 / 20..4 / 0..20 / 20..0 mA• Max load resistance: 500 Ω• Protection: 25 mA

Pry downward on the latch with a screwdri- ver, then round the module to the top.

• Protection: 25 mA • Protection: 25 mA Static relay auxiliary output • Nominal voltage: 24 Vac/dc • Current: 60 mA • Overvoltage protection: 50 V • Settable alarm threshold / hysteresys Response time (10-90%) < 50 ms (without filter) < 200 ms (with filter) < 50 ms (without filter) < 200 ms (with filter) < 40 ms (without filter) < 40/88 ms (with filter) < 40 ms (without filter) < 40/88 ms (with filter) D/Aconversion 1 mV, 2 ΅A 1 mV, 2 ΅A 1 mV, 2 ΅A 1 mV, 2 ΅A 1 mV, 2 ΅A Resolution