Chemist 900 - Industrial emissions analyser - 16 Pages

Add to MyDirectIndustry favorites
Chemist 900 - Industrial emissions analyser

Catalog excerpts

Chemist 900 - Industrial emissions analyser MADE IN ITALY www.seitron.it

 Open the catalog to page 1

INDUSTRIAL ANALYSER Industrial Analyser for Emissions The Chemist 900 industrial analyser can measure and store values of gaseous emissions during the operation of industrial machinery and it can also calculate combustion efficiency . MAIN APPLICATIONS Industrial gas and diesel motors Marine motors Cogeneration groups Industrial Gas Turbines Industrial Burners Emissions measurement of combustion gases post-treatment Industrial glass, ceramic and cement furnaces Furnaces for thermal treatment of metal Chemical and Pharmaceutical process industry Industrial analysis laboratories Biogas...

 Open the catalog to page 2

CHARACTERISTICS AND PERFORMANCE ■■ Measurement of up to 12 gaseous ■■ Auto-zero cycle for gas and pressure emissions simultaneously. 9 gases measured with individual sensors: electrochemical, pellistor, NDIR (Non-Dispersive Infra Red), FLEX series, identical to those used used in the hand held Chemist 500 analysers. Pre-calibrated FLEX-type gas measurement sensors which can be replaced in the field by the user. 3 gases (CO, CO2 e CH4) measured simultaneously with NDIR bench and dedicated anti dust filter. The NDIR bench ensures maximum measurement accuracy for the 3 gases, because there is...

 Open the catalog to page 3

INDUSTRIAL ANALYSER Command Panel CONNECTOR PANEL Mains power Electrical power supply indicator Battery charging indicator 7-pole DIN connector for sensor with heated head Handle for extracting tools from case Auxiliary temperature connector Connector for gas heated probe TcK connector for flue gas temperature sensor TcK connector for combustion / external air temperature sensor Auxiliary sensor connector Flue gas input connector Pressure connector IN positive Clean air input (zero air) Pressure connector IN negative

 Open the catalog to page 4

KEYBOARD / PRINTER PANEL Thermal printer Check Firmware Polycarbonate keyboard with functional touch buttons On/Off button I Configuration Menu I Measurements Menu I Print Menu I Memory Menu | Confirm Data | Exit screen Integrated Bluetooth SmartFlue Mobile New Android App to monitor and save analyses and send via e-mail with smartphones and tablets. Available on the Google Play Store.

 Open the catalog to page 5

INDUSTRIAL ANALYSER Composition: central unit and gas sampling system The Chemist 900 industrial analyser is made up of two parts: ■■ the central unit ■■ the gas sampling system Central Unit Version Anti condensation cyclone cooler with Peltier cell Anti condensation trap N.B. A gas sampling probe with heated head and tube, powered by mains electricity, must always be installed together with the Chemist 902 central unit. GAS SAMPLING SYSTEMS ■■ Passive Type: sensors with different tip lengths and fittings, made of from different materials, with flexible tube connection to the central unit...

 Open the catalog to page 6

Chemist 900 Models CHEMIST 901 ■■ Pneumatic circuit fits from 1 to 9 FLEX series gas measurement sensors: electrochemical, ■■ ■■ ■■ ■■ ■■ ■■ ■■ ■■ ■■ ■■ pellistor, NDIR; the sensors are the same type used in the Chemist 500 portable analysers. They are pre-calibrated and can be field replaced by the user. Sampling vacuum pump. Shut off solenoid valve to perform auto zero cycle with gas sampling probe in the stack Second dilution pump for CO cell protection extends measurement field up to 100,000 ppm. Two external anti-dust filters connected in series with anti-shock protection....

 Open the catalog to page 7

INDUSTRIAL ANALYSER Chemist 900 with passive gas sampling probe and air temperature sensor Chemist 900 with active heated gas sampling probe

 Open the catalog to page 8

Gas sampling systems PASSIVE GAS SAMPLING PROBES Cod Sensor Hose length Maximum operating temperature ACTIVE GAS SAMPLING PROBES Cod Sensor Heated head gas sampling Electro-heated flex tube Carry case N.B. The expansion case storing the heated sensor can be connected to the housing of the Chemist 900 analyser. (The tip of the 1000mm version cannot be inserted in the case because of its length) Connections panel www.seitron.it Expansion case for storing the heated sensor

 Open the catalog to page 9

Measurement ranges and accuracies

 Open the catalog to page 10

MEASUREMENT RESOLUTION RANGE Auxiliary sensor temperature Pressure (draught and differential) Sensor Piezo electric Differential temperature Stack heat loss Efficiency (condensation) Smoke index External instrument Note: *: The NDIR bench always measures the 3 gases CO, CO2 and CH4 Orthogonal view - Chemist 900 w

 Open the catalog to page 11

INDUSTRIAL ANALYSER Technical Features Battery charge: Recharging time: Instrument battery life: 100 .. 240V~ or Li-ion battery pack with internal protection circuit, rechargeable With mains cable with IEC C14 socket. 8 hours for recharge from 0% to 90%. 10 hours of continuous operation (except: printing and Peltier cell group). 2 hours with Cooler active. 4.3" 480×272 pixel backlit TFT graphical colour display. Connectivity Communication port: Bluetooth: TYPE B USB connector. Communication distance: <100 metres (open field). Autozero: Dilution: Automatic autozero cycle with gas sampling...

 Open the catalog to page 12

Gas black: Tightness test (where required): Condensing boiler efficiency : Ambient gases: Draught test: Working temperature: Storage temperature: Humidity limit: Protection level: External dimensions: Weight: Using a manual external pump; the smoke index can be input and printed. Tube gas tightness test with separate receipt printing, using AAKT04 accessory, subject to UNI 7129 (new installations) and UNI 11137: 2012 (existing installations), with automatic calculation of the tube volume. Automatic assessment of the condensing boiler, with calculation and printing of the boiler efficiency....

 Open the catalog to page 13

INDUSTRIAL ANALYSER ACCESSORIES AACCV01 Schuko plug cable. European plug cable. Draught gauge for draught measurement. 100mm Auxiliary temperature sensor PT100 4W, with 3m cable. Combustion air temperature sensor, 200 mm distance, with 3m cable. 180 mm gas sampling probe, extended temperature range to 400°C, with 3m cable. 300 mm gas sampling probe, extended temperature range to 600°C, with 3m cable. 750 mm gas sampling probe, extended temperature range to 800°C, with 3m cable. 1000 mm gas sampling probe, extended temperature range to 1100°C, with 3m cable. 750mm smoke sampling sensor for...

 Open the catalog to page 14

All Seitron SpA catalogs and technical brochures

  1. Magictime plus

    32 Pages

  2. Bluetime

    6 Pages

  3. ACC REL 020 0SE

    1 Pages

  4. Chemist 600

    12 Pages

  5. Chemist 900 ENG

    16 Pages

  6. wireless systems

    16 Pages

  7. ELIOS BASIC

    1 Pages

Archived catalogs