Chemist 100 Be Green - 80 Pages

Add to MyDirectIndustry favorites
Chemist 100 Be Green

Catalog excerpts

Innovation Technology USE AND MAINTENANCE MANUAL Respect your environment: think before printing the full manual on paper

 Open the catalog to page 1

Oseitron Innovation Technology TABLE OF CONTENTS1.0 IMPORTANT INFORMATION06 1.1 Information about this manual06 1.2 Danger levels and other symbols06 2.4    Precautions for the usage of the Li-Ion battery package07 4.5    Pressure sensor, piezoelectric, temperature compensated09 4.7    Draft measurement with    sensor automatic autozero09 7.3.1 Internal battery charge level15 7.3.2 Use with external power pack16 8.1.3    Inserting the probe inside the stack19 8.1.4    Performing the combustion analysis    - Manual mode20 8.1.5    Performing the combustion analysis    - Auto Mode21

 Open the catalog to page 3

Parameter menu Menu→Measures Menu→Measures→Comb. analysis Menu→Measures→Draft Menu→Measures→CO air Menu→Measures→Pressure 12.1 Menu→Configuration 12.2 Menu→Configuration→Analysis 12.2.1 Menu→Configuration→Analysis→Fuel 12.2.2 Menu→Configuration→Analysis→Condensation 12.2.3 Menu→Configuration→Analysis→O2 Reference 12.2.4 Menu→Configuration→Analysis→Measure units 12.2.5 Menu→Configuration→Analysis→Autozero 12.2.6 Menu→Configuration→Analysis→Air temp 12.2.7 Menu→Configuration→Analysis→NOx/NO Ratio 12.3 Menu→Configuration→Instrument 12.3.1 Menu→Configuration→Instrument→Display 12.3.2...

 Open the catalog to page 4

TABLE OF CONTENTS 17.0 TROUBLESHOOTING 18.0 SPARE PARTS AND SERVICING 18.1 Spare parts 18.2 Accessories 18.3 Service Centers ANNEX A - Data Management with “SMARTFLUE LITE MOBILE” APP ANNEX B - Heading of the printed report with the PC software “Easy2print” ANNEX C - Optional measures list ANNEX D - Coefficients of the fuels and Formulas ANNEX E - Declaration of Conformity WARRANTY CERTIFICATE SEITRON S.p.A. a socio unico - ALL RIGHTS RESERVED Total or partial reproduction of this document by any means (including photocopying or storage on any electronic medium) and transmittal of same to...

 Open the catalog to page 5

IMPORTANT INFORMATION 1.1 Information about this manual  This manual describes the operation, the features and the maintenance of Chemist 100 BE GREEN Combustion Analyzer .  Read this operation and maintenance manual before using the device. The user must be familiar with the manual and follow the instructions carefully.  This use and maintenance manual is subject to change due to technical improvements - the manufacturer assumes no responsibility for any mistakes or misprints. 1.2 Danger levels and other symbols The magnets on the back of the instrument can damage credit cards, hard...

 Open the catalog to page 6

©seitron Innovation Technology 2.0 SAFETY 2.1 Safety check • Use the product according to what is described in chapter “Intended purpose”. • During the instrument operation, comply with the current standards. • Do not use the instrument if damaged on the outer cover, on the power supply plug or on the cables. • Do not take measures on non-isolated components / voltage conductors. • Keep the instrument away from solvents. • For the maintenance of the instrument, strictly comply with what’s described in this manual at the “Maintenance” chapter. • All the interventions not specified in this...

 Open the catalog to page 7

©seitron Innovation Technology 3.0 WORKING PRINCIPLE 3.1 General overview of the Analyzer CHEMIST 100 BE GREEN is a portable industrial analyzer for flue gas and emissions monitoring. The instrument is equipped with: - Pneumatic line able to manage up to 3 sensors. - Intuitive user interface; the instrument could be used even without the instruction manual support. - Wide and bright graphic display, White / Black (128x128 pixel), thanks to an efficient backlighting. - Rechargeable 'Li-Ion' battery. Supplied with the device is power supply with 5V —, 2A output to charge the internal...

 Open the catalog to page 8

4.0 DESCRIPTION OF THE PRODUCT 4.1 Working principle The gas sample is taken in through the gas probe, by a diaphragm suction pump inside the instrument. The measuring probe has a sliding cone that allows the probe to be inserted in holes with a diameter of 11 mm to 16 mm and to adjust the immersion depth: it is recommended to have a gas sampling point roughly in the center of the flue/stack. The gas sample is cleaned of humidity and impurities by a condensation trap. The gas is then analyzed in its components by electrochemical cells. This latter guarantees high precision results in a time...

 Open the catalog to page 9

This solution allows great freedom of movement for the operator who is no longer bound directly to the instrument for acquisition and analysis, with significant advantages for many applications. The CHEMIST 100 BE GREEN analyzer is internally equipped with an infrared light interface which uses the HPIR protocol, which allows the communication with a remote IR printer. 4.10 Software and available applications Easy2print PC Software for systems provided with Windows XP or later versions, downloadable from the web site www.seitron.com, allows to insert and to store in the instrument the...

 Open the catalog to page 10

Oseitron Innovation Technology 5.0 COMPONENTS DESCRIPTION 5.1 Instrument interface 111 Polyester keyboard with preformed keys and main command functions:

 Open the catalog to page 11

(2) Display LCD backlit Display, White/Black 128 x 128 pixel with white LEDs. CAUTION: If the instrument is exposed to extremely high or extremely low temperatures, the quality of the display may be temporarily impaired. Display appearance may be improved by acting on the contrast key. Battery status, date and time. Selected menu. Parameters relative to the selected menu. Save Print Context keys. In the various menus the functions change depending on the type of operation being carried out. E B-Type USB connector Connector to connect the device to a personal computer or to the battery...

 Open the catalog to page 12

All Seitron SpA catalogs and technical brochures

  1. Magictime plus

    32 Pages

  2. Bluetime

    6 Pages

  3. ACC REL 020 0SE

    1 Pages

  4. Chemist 600

    12 Pages

  5. Chemist 900 ENG

    16 Pages

  6. wireless systems

    16 Pages

  7. ELIOS BASIC

    1 Pages