| | | WWW.SCOda.it Table SK140-1/E | |
| | | |
| | Heat exchangers water-oil | |
| | | |
| | | |
| | | |
| | | | |
| | | |
| | Size : 200 , 301 , 302 , 502 Other sizes are available on request | | Synthetic fluid: Contact our technical office | |
| | | |
| | | | | |
| | | |
| | | Synthetic fluid: Contact our technical office | |
| | | |
| | | | |
| | | |
| | |~3~| MAIN CHARACTERISTICS | |
| | | |
| | | | | | | | | | Horizontal suggested ( clamping on feet). | | | | | Oil : 12 bar Water: 12 bar | | | | | | | | | | Body : carbon steel Tubes : copper | | | | | Protect the heat exchanger against pressure peaks on exhaust line with a by pass check valve setted at 4 - 5 bar | | | | | Hydraulic oil as per DIN 51524...535; for other fluids contact our technical office | | | | | 15 + 100 mm2/s at 40°C ( ISO VG 15 +100 ) | | | | Fluid contamination class | ISO 19/16, achieved with in line filters at 25 urn and 1325 > 75 (recommended ) | | | | | | | | |
| | | |
| | | |
| | | |
| | | Oll flow Indicated In the table , permit to obtain the best performance. Lower oil flow than minimum reduce the efficency while higher oil flow increase the pressure drop (Ap) whitout efficency improving. | |
| | | |
| | | |
| | | |
| | | | | | | |