External Gear Pump - SCODA - #1

/ 3


catalogue search
External Gear Pump - SCODA
P. 01
External Gear Pump - SCODA
P. 02
External Gear Pump - SCODA
P. 03
Pages:
External Gear Pump - SCODA


See other catalogues for SCODA
You may also be interested in

Accumulator, Flow alarm, Flow switch, Hydraulic pump, Gear pump


Text version of the page
WWW.SCOda.it Table SA060-3/E
Gear pumps type PFG/RO
external gears - fixed displacement - high pressure execution
PFG/RO are fixed displacement exter­nal gear pumps, axial hydraulic balan­cing, for functioning at high pressure, simple and sturdy construction, low noise level.
Suitable for hydraulic oils or synthetic fluids having similar lubricating charac teristics.
Wide variety of displacements: from 1,4 up to 52 cm3/rev.
Max pressure up to 290 bar.
© body © driving gear © driven gear © shaft © inlet port © outlet port
PFG/RO
|T] MODEL CODE
PFG -2
14 /
/RO
**
Fixed displacement gear pump_
Options on request
Hydraulic symbol
OUT
! ' C
*—!
i____,
,_____i
l_
IN
_l
Design number
Size, see section U: 1, 2, 3
RO = high pressure execution
Direction of rotation (as viewed at the shaft end): - = clockwise (supplied standard if not otherwise specified)
S = counterclockwise
Note: PFG are not reversible. The direction of rotation is indicated by an arrow on the pump casing; the same arrow shows also the direction of the oil flow (from the inlet to the outlet port)
Displacement [cm3/rev], see section m for PFG 1: 14, 20, 28, 35, 42, 49, 60 for PFG 2: 07, 10, 11, 14, 16, 18, 21, 27 for PFG 3: 27, 40, 54
Other displacements are available on request
|~2~| OPERATING CHARACTERISTICS at 1450 rpm (based on mineral oil ISO VG 46 at 50°C)
Model
Displacement cm3/rev
Max pressure
(1)
Speed range rpm
Flow
l/min
(2)
Power kW
PFG-114/RO
1,4
800 -
6000
2
1,1
PFG-120/RO
2,1
290 bar
3
1,7
PFG-128/RO
2,8
800 -
5000
4,1
2,3
PFG-135/RO
3,5
270 bar
5,1
2,7
PFG-142/RO
4,1
800 -
4000
5,9
3,1
PFG-149/RO
5,2
260 bar
7,5
3,8
PFG-160/RO
6,2
800
3800
9
4,6
PFG-207/RO
7,0
800
4000
10,1
5,5
PFG-210/RO
9,6
280 bar
600
3000
13,9
7,6
PFG-211/RO
11,5
16,7
9,2
PFG-214/RO
14,1
600
4000
20,4
10,4
PFG-216/RO
16
260 bar
23,2
11,8
PFG-218/RO
17,9
500
3600
25,9
13,2
PFG-221/RO
21,1
230 bar
500
3200
30,6
13,8
PFG-227/RO
28,2
200 bar
500
2500
40,9
16
PFG-327/RO
26
280 bar
500
3000
37,7
20,7
PFG-340/RO
39
270 bar
56,5
29,9
PFG-354/RO
52
260 bar
400
2400
75,4
38,4
(1) For intermittent duty, 20% higher peak pressures are admitted.
(2) Flow rate and power consumption are referred to the max functioning pressure (1) and are proportional to revolution speed.
SA060

pageCatalog pdf di En 2012-06-22-01