SEL-2245-3 Analog Output Module
4Pages

{{requestButtons}}

Catalog excerpts

SEL-2245-3 Analog Output Module - 1

SEL-2245-3 Analog Output Module The SEL-2245-3 provides dc analog outputs for the SEL Axion® platform. Within an Axion system, install as many as sixteen SEL-2245-3 modules with as many as three SEL-2245-3 modules per node. Front Panel Mechanical Installation Each SEL-2242 chassis/backplane has four or ten slots, labeled A–J. Slots B–J support the SEL-2245-3 modules. SEL-2245-3 DC Analog Output Module Schweitzer Engineering Laboratories, Inc. Notch for Module Alignment To install an SEL-2245-3 module, tip the top of the module away from the chassis, align the notch on the bottom of the module (shown in Figure 2) with the slot you want on the chassis, and place the module on the bottom lip of the chassis as Figure 3 illustrates. The module is aligned properly when it rests entirely on the lip of the chassis.

Open the catalog to page 1
SEL-2245-3 Analog Output Module - 2

Output Connections The SEL-2245-3 dc analog outputs include a plus sign to indicate the positive convention. Refer to Specifications for analog output ratings and to Figure 1 for terminal assignments. You can configure outputs to drive ±20 mA or ±10 V signals. Configure outputs by adding a Fieldbus I/O connection for each module in ACSELERATOR RTAC® SEL-5033 Software. See the EtherCAT® section in Section 2: Communications in the SEL-5033 software manual for details. CAUTION Use supply wires suitable for 60°C (140°F) above ambient. See product or manual for ratings. ATTENTION Utilisez des...

Open the catalog to page 2
SEL-2245-3 Analog Output Module - 3

Damp Heat, Cyclic: IEC 60068-2-30:2005 25°C to 55°C, 6 cycles, 95% relative humidity Dielectric Strength and Impulse Tests Operating Temperature Range IIEC 60255-5:2000 IEEE C37.90-2005 Severity Level: 0.5 Joule, 3 kV channel to chassis 0.5 Joule, 3 kV channel to channel Dielectric (HiPot): IEC 60255-5:2000 IEEE C37.90-2005 Severity Level: 2000 Vdc channel to chassis for 1 minute 2000 Vdc channel to channel for 1 minute –40° to +85°C (–40° to +185°F) Note: Not applicable to UL applications. Operating Environment Pollution Degree: Overvoltage Category: Relative Humidity: Maximum Altitude: DC...

Open the catalog to page 3
SEL-2245-3 Analog Output Module - 4

Common Mode IEC 61000-4-16:2002 Disturbance Immunity: Frequency: 0 to 150 Hz Severity Level: Level 4, Segment 4: 30 Vrms open-circuit, 15 to 150 kHz Emissions Radiated and Conducted Emissions: IEC 60255-25:2000 Severity Level: Class A © 2014 by Schweitzer Engineering Laboratories, Inc. All rights reserved. All brand or product names appearing in this document are the trademark or registered trademark of their respective holders. No SEL trademarks may be used without written permission. SEL products appearing in this document may be covered by U.S. and Foreign patents. 2350 NE Hopkins Court...

Open the catalog to page 4

All Schweitzer Engineering Laboratories catalogs and technical brochures

  1. SEL-C662

    1 Pages

  2. 2019 CATALOG

    248 Pages

  3. 2018 CATALOG

    374 Pages