Telemecanique Osiprox Inductive Brochure - Schneider Electric Sensor Competency Center - #1 |
|
You may also be interested in
RFID reader, Photoelectric sensor, Float level switch, Retro-reflective sensor, Capacitive sensor
Text version of the page
Osiprox
!
DIA4ED1031205 V1.1 01/2004
Innovation
through intelligence
“a single product that
automatically adapts
to all installation
environments”
Welcome to the Telemecanique
Simply Smart world
With Osiconcept®, the intelligent
self-teaching of the metal environment
makes selection and setting-up easier
and integration in the machine is improved
due to the compactness of the flat design.
A simple press on the button
automatically configures the
sensor and provides
optimal performance
irrespective of the
installation
method (flush,
non flush).
, inductive proximity sensors
Form E Form C Form D M12 M18 M30
Connection pre-cabled, L = 2 m M8 or 1/2" 20 UNF
connector
Accessories (to be ordered separately)
Composition of reference
XS8E1A1PAL2
Connection: L2 = pre-cabled, length 2 m
M12 = M12 connector
M8 = M8 connector
U20 = 1/2" UNF
Output: A = NO, B = NC
Output: P = PNP, N = NPN, M = a.c./d.c.
Material: A = plastic, B = metal
Form: J, F, E, C, D, M8, M12, M18, M30
Range: 8 = Universal Osiconcept® flat,
6 = Universal cylindrical,
7 = Optimum flat,
5 = Optimum cylindrical
Fixings
flat
XSZBE00
XSZBC00
–
substitution of block
type sensors
XSE / XSC / XSD
XSZBE10
XSZBC10
XSZBD10
90°
XSZBE90
XSZBC90
–
Form E
Form C
Form D
For flat sensors
forms E, C and D
XSZB108
XSZB112
XSZB118
XSZB130 XSZBPM12
M8
M12
M18
M30
With indexing pin for cylindrical sensors For XS6 Osiconcept® remote control
Universal
Dimensions (mm) W x H x D or Ø x L 26 x 26 x 13
f lush or non f lush mountable via Osiconcept® teach mode f lush or non f lush mountable via Osiconcept® Suitability for flush mounting in metal teach mode
Nominal sensing distance Sn (mm) Flush and non flush mountable 10 15
c 3-wire d.c. PNP NO function (1)
z 2-wire a.c./d.c. without
short-circuit protection
NO function
NPN NO function (1)
XS8E1A1PAL2
XS8E1A1NAL2
XS8E1A1MAL2
NC function XS8E1A1MBL2
XS8E1A1PAM8
XS8E1A1NAM8
XS8E1A1MAL01U20
XS8E1A1MBL01U20
pre-cabled, L = 2 m
80 x 80 x 26
40 60
XS8D1A1PAL2
XS8D1A1NAL2
XS8D1A1MAL2
XS8D1A1MBL2
M12 or U20 connector
XS8D1A1PAM12
XS8D1A1NAM12
XS8D1A1MAU20
XS8D1A1MBU20
M12 connector on flying lead
M12 x 54
3.4 5
XS612B2PAL01M12
XS612B2NAL01M12
–
–
M12 connector on flying lead
M18 x 67
6 9
XS618B2PAL01M12
XS618B2NAL01M12
–
–
M12 connector on flying lead
M30 x 71
11 18
XS630B2PAL01M12
XS630B2NAL01M12
–
–
pre-cabled, L = 2 m
40 x 40 x 15
Case material plastic plastic plastic metal metal metal
15 25
XS8C1A1PAL2
XS8C1A1NAL2
XS8C1A1MAL2
XS8C1A1MBL2
M8 or 1/2" 20 UNF
connector
XS8C1A1PAM8
XS8C1A1NAM8
XS8C1A1MAL01U20
XS8C1A1MBL01U20
Supply voltage
(1) For NC versions, replace "A" by "B". Example: XS8E1A1PAL2 becomes XS8E1A1PBL2
The above products are only a selection of the most popular products, for other versions: please refer to the Detection Components catalogue.
Flush mountable Non flush mountable
M8 M12 M18 M30
Connection
Universal increased range
Dimensions (mm) Ø x L
Suitability for flush mounting in metal flush mountable flush mountable flush mountable flush mountable
Nominal sensing distance Sn (mm) Flush mountable
c 3-wire d.c. PNP NO function (1)
z 2-wire a.c./d.c. without
short-circuit protection
NO function
NPN NO function (1)
NC function
pre-cabled, L = 2 m
M8 x 50
2.5
XS608B1PAL2
XS608B1NAL2
–
–
M12 connector
XS608B1PAM12
XS608B1NAM12
–
–
pre-cabled, L = 2 m
M12 x 50
4
XS612B1PAL2
XS612B1NAL2
XS612B1MAL2
XS612B1MBL2
M12 or U20 connector
XS612B1PAM12
XS612B1NAM12
XS612B1MAU20
XS612B1MBU20
pre-cabled, L = 2 m
M18 x 60
8
XS618B1PAL2
XS618B1NAL2
XS618B1MAL2
XS618B1MBL2
M12 or U20 connector
XS618B1PAM12
XS618B1NAM12
XS618B1MAU20
XS618B1MBU20
pre-cabled, L = 2 m
M30 x 60
15
XS630B1PAL2
XS630B1NAL2
XS630B1MAL2
XS630B1MBL2
M12 or U20 connector
XS630B1PAM12
XS630B1NAM12
XS630B1MAU20
XS630B1MBU20
Case material metal metal metal metal
Supply voltage
Flush mountable
"CLICK!"
Under no circumstances must the referencing grid be used to compose a reference
|
|