Two-hand control panels AZR 201 TH Technical data
Standards:IEC/EN 60204-1, EN 954-1, BG-GS-ET-20 Stop category2x Stop 0 Control category:4 Enclosure:glass-fibre reinforced thermoplastic Termination:screw terminals Cable section:max. 2.5 mm >
2 solid or multi-strand lead (incl. conductor ferrules) U >
e :24 VAC, 115 VAC, 230 VAC –15%/+6%, 50/60 Hz I >
e :0.1 AProtection class:terminals IP 20 enclosure IP 40 to EN 60529 Power consumption:max. 4.0 WMax.
industrial fuse rating:Si1 (internal): 125 mAT •Safety-monitoring module to monitor two-hand controls to EN 574-1 III C•2 enabling paths, Stop 0•1 auxiliary NC contact with antivalent functioning principle (auxiliary contacts are not to be used in safety circuits)•Feedback circuit•4 LEDs to show operating conditions•Control Category 4 to EN 954-1 Si2: 80 mAT Feedback circuit:yes Drive circuits:S11/S23, S31/S43: max. 28 VDC Enabling contacts:2 enabling paths Switching capacity:enabling paths: 6 A/230 VAC, 6 A/24 VDC Fuse rating:enabling paths: 6 A slow blow Utilisation category:AC-15, DC-13 Signalling contacts:1 NC contact Switching capacity:Indicating contact: 2 A/24 VDC Contact material:AgSnO, self-cleaning, positive action Contact resistance:max. 100 m >
Ω
in new condition Pull-in delay: ≤ 20 ms Response time: ≤ 10 ms Air clearances and creepage distances: DIN VDE 0110-1 (04.97), 2.4 kV/2 Overvoltage category:III to DIN VDE 0110 Degree of pollution:2 to DIN VDE 0110 Ambient temperature:0 °C … + 40 °C (Derating curve on request) Mechanical life:10 million operations Function display:4 LEDs Weight:360 g Dimensions:45 x 83 x 140 mm Approvals >
H
Ordering details
AZR 201 TH >
➀
No. Replace Description >
➀
24 VAC24 VAC115 VAC115 VAC230 VAC230 VAC >
2-22