Solenoid interlocks AZM 170 Technical data Contact variants

Standards:IEC/EN 60947-5-1BG-GS-ET-19Enclosure:glass-fibre reinforced thermoplastic, self-extinguishingActuator and locking bolt:stainless steel 1.4301Protection class:IP 67 to EN 60529Contact material:silverContact type:change-over contact with double break, type Zb or 2 NC contacts, with galvanically separated contact bridgesSwitching system: Power to unlock1 NO / 1 NC 2 NC Power to lock1 NO / 1 NC 2 NC contactsConnectorPower to unlock1 NO / 1 NC 2 NC

A1A2

1422213213

A1A2

1222213211 22 A IEC 60947-5-1slow action, NC contacts with positive breakTermination:cut clamp terminals (IDC method) Cable section:0.75 1.0 mm

A1A2

1422213213 31 6023 4,2 1590 24 2 , flexibleU

A1A2

imp :4 kVU
1222213211 i :250 VI
830 the :10 AUtilisation category:AC-15, DC-13I
e /U
e :4 A / 230 VAC4 A / 24 VDCMax. industrial fuse rating:6 A gL/gG D-fusePositive break travel:11 mmPositive break force:6 N for each NC contact fittedMagnet:100% EDU Thermoplastic enclosure Compact design Manual release Long life Double insulated

A1A2

X
1422213213 High holding force 1000 N 30 N latching force Insulation displacement connector Power to unlock/power to lock principle 1 cable entry M16 x 1.5 Individual coding available on request
s :24 VAC/DC110 VAC, 50/60 Hz230 VAC, 50/60 HzPower consumption:max. 10 WAmbient temperature: 25 C + 60 CMechanical life:> 1 million operationsF
11223344

A1A2

1222213211 max :1000 NLatching force:30 N
11223344 Approvals

H E C D

Ordering details Note

AZM 170

-

z

k

-

-

-

No. Replace Description No. Replace Description

Cut clampSKScrew terminals

24 VAC/DCUs 24 VAC/DC110 VACUs 110 VAC230 VACUs 230 VAC

111NO/1NC 022NC

Manual release2197Manual release from side1637Gold-plated contacts

Latching force 5 NrLatching force 30 N

Power to unlockaPower to lock Manual release (left) For manual release using M5 triangular key,available as accessory Included in standard version

Cable glandSTConnector M 12 x 1ST-2431Connector M 12 x 1, withindividual solenoid monitoring Manual release from side (right) Additional manual release on side, ordering suffix -2197 Only available for power to unlock principle