| | | Contact variants | | |
| | | AZ 355 | | Technical data | | |
| | | |
| | | Standards: Enclosure: Actuator: Protection class: Contact material: Contact type: | | IEC/EN 60947-5-1 BG-GS-ET-15 light-alloy diecast, paint finish stainless steel 1.4301 IP 67 to EN 60529 silver change-over contact with double break, type Zb or 2 NC or 3 NC contacts, with galvanically separated contact bridges | | 1 NO/ 1 NC 13—-r—U 21-^—22 | | |
| | | |
| | | 2 NC 21 ^— | | |
| | | -12 -22 | | |
| | | |
| | | |
| | | |
| | | 1 NO/2 NC | | |
| | | |
| | | 132131- | | -14 -22 -32 | | |
| | | |
| | | |
| | | Switching system: | | 0 IEC 60947-5-1
| | |
| | | |
| | | |
| | | slow action, NC contact with positive break screw terminals max. 1.5 mm2, min. 0.75 mm2 (incl. conductor ferrules) | | |
| | | 3 NC | | |
| | | |
| | | -12 -22 -32 | | |
| | | Termination: Cable section: | | |
| | | |
| | | |
| | | |
| | | Cable entry: Uimp: Ui: 'the: Utilisation category: Ie/Ue: Max. fuse rating: Positive break travel: Positive break force: Ambient temperature: Mechanical life: Latching force: | | 3 x M20 x 1.5 2 contacts: 6 kV 3 contakts: 4 kV 2 contacts: 500 V 3 contakts: 250 V 10 A AC-15 4 A / 230 VAC 4 A / 24 VDC 6 A gL/gG D-fuse 10.7 mm 5 N for each NC contact fitted - 30 °C ... + 90 °C 10 million operations 30 N for ordering suffix r | | Connector 1 NO/ 1 NC [2^^122" | | |
| | | |
| | | • Metal enclosure • Up to 3 contacts • Multiple coding • Long life • High level of contact reliability with low voltages and currents • Mounting details to EN 50041 • 3 cable entries • Actuator heads can be repositioned in steps 4 x 90° • Can be mounted on a flat surface • Transverse and longitudinal slotted holes • Available with LED | | |
| | | 2 NC | | |
| | | |
| | | |
| | | |
| | | Approvals | | |
| | | |
| | | Ordering details | | |
| | | Note | | Note | | |
| | | |
| | | |
| | | AZ 355-©-z©k-®-©-© | | |
| | | |
| | | | | | | | | | | No. | Replace | Description | | | | | 11 | 1 NO/1 NC | | | | | 02 | 2 NC | | | | | 03 | 3 NC | | | | | 12 | 1 NO/2 NC | | | | © | | Latching force 5 N | | | | | r | Latching force 30 N | | | | | ü | With overlapping | | | | | | contacts | | | | © | G24 | With LED | | | | © | | Cable entry M 20 | | | | | NPT | Cable entry NPT 1/2" | | | | | ST | Connector M 12 x 1 | | | | © | 1637 | Gold-plated contacts | | | | | | | | | | |
| | | LED version: Ordering suffix G24, only available for version with one NO and one NC contact. Protected against incorrect polarity and voltage spikes. Actuators must be ordered separately. | | By turning the head in 90° steps, 8 actuating planes are possible. A Torx T10 screwdriver is needed for this purpose. | | |
| | | |
| | | Even when the screw is removed, the head is self-retaining. The switch can industrial still not be tampered. | | |
| | | |
| | | |
| | | 1-11 | | |
| | | BCHFT1ER5RL | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |