| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | |
| | | | | |
| | | |
| | | TV.S 355 | | Contact variants | | |
| | | Technical data | | |
| | | |
| | | Standards: Design: Enclosure: Protection class: Contact material: Contact type: | | IEC/EN 60947-5-1 BG-GS-ET-15 fixings to EN 50041 light-alloy diecast, paint finish IP 67 to EN 60529 silver change-over contact with double break Zb or 1 NC or 2 NC contacts, with galvanically separated contact bridges 0 IEC 60947-5-1 slow action, NC contact with positive break screw terminals max. 2.5 mm2 (incl. conductor ferrules) 3 x M20 x 1.5 6 kV 500 V 10 A AC-15, DC-13 4 A / 230 VAC 1 A / 24 VDC 6 A gL/gG D-industrial fuse - 25 °C ... + 70 °C > 1 million operations max. 1000/h 0 8 mm / 10 mm 7° 0.6 Nm | | 1 NO/ 1 NC 354' 3' 0 3' 354' | | |
| | | |
| | | 13-14 21-22 | | |
| | | |
| | | (p)T | | (ST | | |
| | | |
| | | |
| | | 2 NC 354' | | |
| | | 3 03 | | 354 | | |
| | | |
| | | 11-12 21-22 | | |
| | | | |
| | | (ST | | |
| | | |
| | | Connector 1 NO/ 1 NC fr 12 3 4 | | |
| | | Switching system: | | |
| | | |
| | | Termination: Cable section: Cable entry: Uimp: Ui: 'the: Utilisation category: Ie/Ue: | | |
| | | |
| | | 2 NC 11 21 | | |
| | | |
| | | • Metal enclosure • Good resistance to oil and petroleum spirit • Actuator heads can be repositioned in steps 4 x 90° using Torx T 20 srewdriver and pin • Actuator shaft can be turned 360° • 3 cable entries M20 x 1.5 • LED version available | | |
| | | |
| | | Max. fuse rating: Ambient temperatureMechanical life: Switching frequencyShaft bore: Positive break angle: Positive break torque | |
| | | |
| | | | |
| | | |
| | | Approvals H I ® D | | |
| | | |
| | | dering details | | Note | | Note | | |
| | | |
| | | |
| | | TV S 355-©z-@ | | |
| | | Closed guard device = 0° in contact switch travel diagrams. This is the rest position of switch. • Setting assistance: Grub screw for location, shaft pre-drilled for pin • Industrial universal joint available to compensate for axial displacement (only for shaft bore 10 mm), see the following pages 1-75 | | |
| | | | | | | | | | | No. | Replace | Description | | | | | 8 | Shaft bore 0 8 mm | | | | | 10 | Shaft bore 0 10 mm | | | | | 11 | 1 NO / 1 NC | | | | | 02 | 2 NC | | | | | | Cable entry M20 | | | | | NPT | Cable entry NPT 1/2" | | | | | ST | Connector M12 | | | | | | (A-Coding) | | | | | 2310 | (B-Coding) | | | | | | | | | | |
| | | 24 VDC | | |
| | | |
| | | L- | | |
| | | |
| | | |
| | | LED version: Ordering suffix G24, only available for version with one NO and one NC contact. Protected against incorrect polarity and voltage spikes. | | |
| | | |
| | | |
| | | 1-69 | | |
| | | 5CHIT1ER5RL | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |