Catalogue Safety sensors
www.schmersal.com
print switch display
Page / 50
Contact the
Manufacturer
Where to buy
this product ?
Request
a Quote
SCHMERSAL - 143682, 4859, 68308, 14568
/ 50
See other catalogues for SCHMERSAL
Text version of the page
Contact variants
BZ 16
Technical data
Standards: IEC 60947-5-3
BG-GS-ET-14
1 NO/ 1 NC
1
f
0 0
0 0
0 0
E E
□ □
s 0
DU 21 22 2tVEC
Design: Enclosure:
rectangular glass-fibre reinforced
thermoplastic, self-extinguishing
Protection class: Termination: Cable section:
Cable entry: Mode of operation:
Actuating magnet: Control category:
IP 67 to EN 60529 screw terminals max. 2 x 1.5 mm2 (incl. conductor ferrules) 3 x M20 x 1.5 non-contacting, through coded industrial actuator BZ 16-B1, coded up to 4
2 NC
□ EE
11 12
21 22
24VDC
to EN 954-1
in combination with a safety monitoring module
Classification:
Sao: Sar:
up to PDF-M
to IEC 60947-5-3
in combination with a safety monitoring module 10 mm (minimum distance 2 mm in case of approach from side) 20 mm (minimum distance 2 mm
• With integral evaluation
• With coding
• Long life, no mechanical wear
• Protection class IP 67
• Intensitive to transverse misalignment
• Intensitive to soiling
• Wiring compartment
• Suitable for food processing industry
• Mounting dimensions identical to AZ 16
• 3 cable entries M20 x 1.5
in case of approach from side) Max. switching voltage without LED: 250 VAC Max. switching current without LED: 4:00:00 Max. switching capacity without LED: 1000 W
Outputs: Ue:
Max. industrial fuse rating: Utilisation category: Ie/Ue:
Power consumption: Response time: Switch-on time: Ambient temperature: Storage and transport temperature: Max. switching frequency: Resistance to shock: Resistance to vibration:
2 enabling paths 2 NC or 1 NO / 1 NC 24 VDC 2.5 A
4 A gL/gG D-fuse AC-15, DC-13 2.5 A / 250 VAC 2.5 A / 24 VDC < 4 W 15 ms 60 ms 0 °C ... + 55 °C
- 20 °C ... + 70 °C 1 Hz 30 g / 11 ms 10 ... 55 Hz, amplitude 1 mm
Ordering details ■ Note ■ Note
Enabling zone 3 different directions of actuation:
cover, front and below
Actuator BZ 16-B1 must be ordered separately.
Contact symbols shown for the closed condition of the guard device.
1-86
5CHIT1ER5HL
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
pdf-page pdf di En 2009-01-02-09