| | | Contact variants | | |
| | | BZ 16 | | Technical data | | |
| | | |
| | | Standards: IEC 60947-5-3 BG-GS-ET-14
| | 1 NO/ 1 NC | | |
| | | |
| | | | | | | | | | | | | | | | | 1 | f | | | | 0 0 | 0 0 | 0 0 | | | | E E | □ □ | s 0 | | | | DU 21 22 2tVEC | | | | | | | | | | | |
| | | |
| | | Design: Enclosure: | | rectangular glass-fibre reinforced | | |
| | | |
| | | thermoplastic, self-extinguishing | | |
| | | |
| | | Protection class: Termination: Cable section: Cable entry: Mode of operation: Actuating magnet: Control category: | | IP 67 to EN 60529 screw terminals max. 2 x 1.5 mm2 (incl. conductor ferrules) 3 x M20 x 1.5 non-contacting, through coded industrial actuator BZ 16-B1, coded up to 4 | | |
| | | |
| | | 2 NC | | |
| | | |
| | | □ EE | | |
| | | |
| | | 11 12 | | 21 22 | | 24VDC | | |
| | | |
| | | |
| | | to EN 954-1 in combination with a safety monitoring module | | |
| | | |
| | | Classification: Sao: Sar: | | up to PDF-M to IEC 60947-5-3 in combination with a safety monitoring module 10 mm (minimum distance 2 mm in case of approach from side) 20 mm (minimum distance 2 mm | | |
| | | • With integral evaluation • With coding • Long life, no mechanical wear • Protection class IP 67 • Intensitive to transverse misalignment • Intensitive to soiling • Wiring compartment • Suitable for food processing industry • Mounting dimensions identical to AZ 16 • 3 cable entries M20 x 1.5 | | |
| | | |
| | | in case of approach from side) Max. switching voltage without LED: 250 VAC Max. switching current without LED: 4:00:00 Max. switching capacity without LED: 1000 W | | |
| | | |
| | | Outputs: Ue: Power consumption: Response time: Switch-on time: Ambient temperature: Storage and transport temperature: Max. switching frequency: Resistance to shock: Resistance to vibration: | | 2 enabling paths 2 NC or 1 NO / 1 NC 24 VDC 2.5 A 4 A gL/gG D-fuse AC-15, DC-13 2.5 A / 250 VAC 2.5 A / 24 VDC < 4 W 15 ms 60 ms 0 °C ... + 55 °C - 20 °C ... + 70 °C 1 Hz 30 g / 11 ms 10 ... 55 Hz, amplitude 1 mm | | |
| | | |
| | | |
| | | |
| | | Ordering details ■ Note ■ Note | | |
| | | |
| | | Enabling zone 3 different directions of actuation: cover, front and below Actuator BZ 16-B1 must be ordered separately. Contact symbols shown for the closed condition of the guard device. | | |
| | | |
| | | 1-86 | | |
| | | 5CHIT1ER5HL | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |