Standards:IEC/EN 60204-1EN 60947-5-3EN 954-1BG-GS-ET-14 BG-GS-ET-20 Stop category0 Control category:1 to EN 954-1 Start conditions:Automatic Start-up test:no Enclosure:glass-fibre reinforced thermoplastic Mounting:snaps onto standard DIN rail to EN 50022 Termination:screw terminals •Control Category 1 to EN 954-1•Classification PDF-S to EN 60947-5-3 incombination with BNS safety sensors•1 enabling path
•Monitoring of BNS range magnetic safety sensors•LED function display•Operating voltage 24 VDC Cable section:max. 1.5 mm >
2 (incl. conductor ferrules)Protection class:terminals IP 20 enclosure IP 40 to EN 60529 U >
e :24 VDC ±15% I >
e :0.1 A Power consumption:2.5 W Monitored inputs2 x 2 NC / 1 NO Feedback circuit:no Max. cable length:100 m of 0.75 mm >
2 conductor Enabling contacts:1 enabling path Utilisation category:AC-15, DC-13I >
e /U >
e :2 A / 250 VAC 2 A / 24 VDC Contact load capacity:max. 250 VAC, max. 5 A (cos >
Ï•
= 1) Max.
industrial fuse rating:5 A gL/gG D-fuse Function display:LED EMC rating:conforming to EMC Directive Max. switching frequency:10 Hz Overvoltage category:II to DIN VDE 0110 Degree of pollution:3 to DIN VDE 0110 Resistance to vibration:10 ... 55 Hz / amplitude 0.35 mm, ±15 % Resistance to shock:30 g / 11 ms Ambient temperature:0 °C … + 55 ºC Storage and transport temperature:– 25 °C … + 70 ºC Dimensions:48 x 96 x 58 mmNote:Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. Approvals >
H C D
Ordering details
AES 6112 >
➀
No. Replace Description >
➀
24 VDC >
1-126