Safety sensors AES 3075 Technical data

Standards:IEC/EN 60204-1EN 60947-5-3EN 954-1BG-GS-ET-14 BG-GS-ET-20 Stop category0 Control category:3 Start conditions:automatic or start button Start-up test:no Enclosure:glass-fibre reinforced thermoplastic Mounting:snaps onto standard DIN rail to EN 50022 Termination:screw terminals •Control Category 3 to EN 954-1•Classification PDF-M to EN 60947-5-3 incombination with BNS safety sensors•2 safe transistor outputs •Enable delay time can be modified•Monitoring of BNS range magnetic safety sensors•To monitor 4 guard industrial doors for ControlCategory 3 to EN 954-1•Can be modified from NO-NC to NC-NC contact combination for each guard door•Feedback circuit•Cross-wire monitoring•ISD Integral System Diagnostics •Operating voltage 24 VDC•Connection of input expander possible Cable section:max. 4 mm
2 (incl. conductor ferrules)Protection class:terminals IP 20 enclosure IP 40 to EN 60529 U
e :24 VDC ±15%I
e :0.3 A without external contactors and additional outputs Monitored inputs4 x 1 NC / 1 NO or 2 NC Feedback circuit:yes Input resistance:approx. 2 k

Ω

to ground Input signal „1“:10 ... 30 VDC Input signal „0“:0 ... 2 VDC Max. cable length:1000 m of 0.75 mm
2 conductorEnabling contacts:2 safe transistor outputs: each 700 mA, short-circuit proof Max. industrial fuse rating:4 A gL/gG D-fuse Signalling output:Y1-Y5 = max. 250 mA, p-type, short-circuit proof Function display:LED (ISD) EMC rating:conforming to EMC Directive Max. switching frequency:3 Hz Overvoltage category:II to DIN VDE 0110 Degree of pollution:3 to DIN VDE 0110 Resistance to vibration:10 ... 55 Hz / amplitude 0.35 mm, ±15 % Resistance to shock:30 g / 11 ms Ambient temperature:0 °C … + 55 ºC Storage and transport temperature:– 25 °C … + 70 ºC Dimensions:100 x 75 x 110 mmNote:Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. Approvals

H

Ordering details Function table

AES 3075

➀

Additional transistor output: Function: No. Replace Description Y1 Guard door 1 openY2 Guard door 2 open Y3 Guard door 3 openY4 Guard door 4 openY5 System O.K.

➀

24 VDC

1-124

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
pdf-page pdf di En 2008-10-42-14