Standards:IEC/EN 60204-1EN 60947-5-3EN 954-1BG-GS-ET-14 BG-GS-ET-20 Stop category0 Control category:3 Start conditions:automatic or start button Start-up test:no / yes Enclosure:glass-fibre reinforced thermoplastic Mounting:snaps onto standard DIN rail to EN 50022 Termination:screw terminals Control Category 3 to EN 954-1Classification PDF-M to EN 60947-5-3 incombination with BNS safety sensors3 enabling paths
Monitoring of BNS range magnetic safety sensorsNO/NC contact combination can be connectedCross-wire monitoringISD Integral System DiagnosticsAvailable for various operating voltagesShort-circuits proof additional transistor outputFeedback circuit to monitor external relaysStart functionConnection of input expander possible
Additional contacts by means of output expander Cable section:max. 4 mm >
2 (incl. conductor ferrules)Protection class:terminals IP 20 enclosure IP 40 to EN 60529U >
e :AES 2335/2336: 24 VDC 15 %AES 2335.1/2336.1: 110 VAC
AES 2335.2/2336.2: 230 VAC AES 2335.3: 24 VAC I >
e :0.2 A (DC version) Power consumption:5.8 W Feedback circuit:yes Monitored inputs1 NC / 1 NO Input resistance:approx. 2 k >
Ω
to ground Input signal 1:10 ... 30 VDC Input signal 0:0 ... 2 VDC Max. cable length:1000 m of 0.75 mm >
2 conductor Enabling contacts:3 enabling paths Utilisation category:AC-15, DC-13I >
e /U >
e :2 A / 250 VAC 2 A / 24 VDC Contact load capacity:max. 250 VAC, max. 3 A (cos >
ϕ
= 1) Max.
industrial fuse rating:3 A gL/gG D-fuseSignalling output:2 transistor outputs, Y1 + Y2 = max. 100 mA, p-type, short-circuit proof Function display:LED (ISD) EMC rating:conforming to EMC Directive Max. switching frequency:5 Hz Overvoltage category:II to DIN VDE 0110 Degree of pollution:3 to DIN VDE 0110 Resistance to vibration:10 ... 55 Hz / amplitude 0.35 mm, 15 % Resistance to shock:30 g / 11 ms Ambient temperature:0 C + 55 C Storage and transport temperature: 25 C + 70 C Dimensions:55 x 75 x 110 mmNote:Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. Approvals >
H C D
Ordering details Function table
AES 233 >
➀➁
Additional transistor output: Function / Switching condition: No. Replace Description Y1 Authorized operation, enabling paths closedY2 No authorized operation, enabling paths open >
➀
5Without start-up test6With start-up test >
➁
24 VDC.1110 VAC.2230 VAC
.324 VAC >
1-122