Standards:IEC/EN 60204-1EN 60947-5-3EN 954-1BG-GS-ET-14 BG-GS-ET-20 Stop category0 Control category:3 Start conditions:automatic or start button (optionally monitored) Start-up test:no Enclosure:glass-fibre reinforced thermoplastic, ventilated Mounting:snaps onto standard DIN rail to EN 50022 Termination:plug-in, screw terminals •Control Category 3 to EN 954-1•Classification PDF-M to EN 60947-5-3 incombination with BNS safety sensors•6 x dual-channel control
•2 enabling paths•Additional output•electronic protection•Monitoring of BNS range magnetic safety sensors•To monitor 6 guard doors for Control Category 3 to EN 954-1•Cross-wire monitoring•Feedback circuit to monitor external relays•Start-function with trailing edge (optional)
•Plug-in screw terminals•Operating voltage 24 VDC•Connection of input expander possible•Additional contacts by means of output expander•Individual signal outputs for each guard door Cable section:max. 2.5 mm >
2 (incl. conductor ferrules) Protection class:IP 20 to EN 60529U >
e :24 VDC – 15 % / + 20 % 24 VAC – 15 % / + 10 % I >
e :0.11 A Monitored inputs6 x 1 Ö / 1 S Feedback circuit:yes Input resistance:approx. 2.9 (channel 1)/0.36 (channel 2) k >
Ω
to ground Input signal „1“:19 ... 28.8 VDC Input signal „0“:0 ... 2 VDC Max. cable length:500 m of 0.75 mm >
2 conductor Enabling contacts:2 enabling paths Utilisation category:AC-15, DC-13I >
e /U >
e :6 A / 250 VAC 6 A / 24 VDC Contact load capacity:max. 250 VAC, max. 6 A (cos >
Ï•
= 1) Max.
industrial fuse rating:6 A gL/gG D-fuse Signalling output:6 relay outputs 6 x 20 mA, short-circuit proof Function display:3 LEDs EMC rating:conforming to EMC Directive Max. switching frequency:3 Hz Overvoltage category:II to DIN VDE 0110 Degree of pollution:3 to DIN VDE 0110 Resistance to vibration:10 ... 55 Hz / amplitude 0.35 mm, ±15 % Resistance to shock:30 g / 11 ms Ambient temperature:– 25 °C … + 45 °C Storage and transport temperature:– 25 °C … + 70 ºC Dimensions:45 x 120 x 121 mm Weight:300 gNote:Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. Approvals >
H C D
in preparation >
Ordering details Function table
AES 2285 >
➀
Additional transistor output: Function / Switching condition: No. Replace Description Y1 Guard door 1 closedY2 Guard door 2 closed
Y3 Guard door 3 closedY4 Guard door 4 closedY5 Guard door 5 closedY6 Guard door 6 closed >
➀
24 VDC >
1-120