Standards:IEC/EN 60204-1EN 60947-5-3EN 954-1BG-GS-ET-14 BG-GS-ET-20 Stop category0 Control category:3 Start conditions:automatic or start button Start-up test:no / yes Enclosure:glass-fibre reinforced thermoplastic, ventilated Mounting:snaps onto standard DIN rail to EN 50022 Termination:screw terminals •Control Category 3 to EN 954-1•Classification PDF-M to EN 60947-5-3 incombination with BNS safety sensors•2 enabling paths
•Enable delay time can be modified•Monitoring of BNS range magnetic safety sensors•Cross-wire monitoring with NO-NC contact combination•ISD Integral System Diagnostics•Short-circuits proof additional transistor output•Feedback circuit to monitor external relays•Start function
•Operating voltage 24 VDC•Can be changed from NO/NC to NC/NC contact combination•Connection of input expander possible•Additional contacts by means of output expander Cable section:max. 2.5 mm >
2 (incl. conductor ferrules) Protection class:IP 20 to EN 60529 U >
e :24 VDC ±15% I >
e :0.2 A Monitored inputs1 NC / 1 NO or 2 NC Feedback circuit:yes Input resistance:approx. 4 k >
Ω
to ground Input signal „1“:10 ... 30 VDC Input signal „0“:0 ... 2 VDC Max. cable length:1000 m of 0.75 mm >
2 conductor Enabling contacts:2 enabling paths Utilisation category:AC-15, DC-13I >
e /U >
e :3 A / 230 VAC 2 A / 24 VDC Contact load capacity:max. 250 VAC, max. 6 A (cos >
Ï•
= 1) Max.
industrial fuse rating:6 A gL/gG D-fuseSignalling output:2 transistor outputs, Y1 + Y2 = max. 100 mA, p-type, short-circuit proof Function display:LED (ISD) EMC rating:conforming to EMC Directive Max. switching frequency:1 Hz Overvoltage category:II to DIN VDE 0110 Degree of pollution:3 to DIN VDE 0110 Resistance to vibration:10 ... 55 Hz / amplitude 0.35 mm, ±15 % Resistance to shock:30 g / 11 ms Ambient temperature:0 °C … + 55 ºC Storage and transport temperature:– 25 °C … + 70 ºC Dimensions:22.5 x 100 x 121 mmNote:Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. Approvals >
H C D
in preparation >
Ordering details Function table
AES 123 >
➀
Additional transistor output: Function / Switching condition: No. Replace Description Y1 Authorized operation, enabling paths closedY2 No authorized operation, enabling paths open >
➀
5Without start-up test6With start-up test >
1-110