| | | BNS 33 | | Contact variants | | |
| | | Technical data | | |
| | | |
| | | Standards: IEC 60947-5-3 BG-GS-ET-14
| | 1 NO/ 1 NC BK 13.—-#14 BU WH 21 22 BN 1 NO/2 NC | | |
| | | |
| | | Design: Enclosure: Protection class: Termination: Cable section: Mode of operation: Actuating magnet: Control category: | | rectangular glass-fibre reinforced thermoplastic IP 67 to EN 60529 Boflex cable, suffix -ST: M8 x 1 connector manufacturer 4 x 0.25 mm2 magnetic BPS 33, BPS 33-2326, coded up to 4 | | |
| | | |
| | | BK 22-WH 32. | | Ï14 BU -C BN | | |
| | | |
| | | |
| | | 1 NO/2 NC (ordering suffix -2187) | | |
| | | |
| | | GY 13. GN 21 . WH 31 . | | 14 PK 22 YE -32 BN | | |
| | | |
| | | |
| | | to EN 954-1 in combination with a safety monitoring module | | |
| | | 2 NC (ordering suffix -2187) | | |
| | | |
| | | |
| | | Classification: | | up to PDF-M | | |
| | | ¿12 BU -22 BN | | |
| | | BK 11 . WH 21 . | | |
| | | |
| | | to IEC 60947-5-3 in combination with a safety monitoring module Sao: 5 mm (BPS 33) 8 mm (BPS 33-2326) Sar: 15 mm (BPS 33) 15 mm (BPS 33-2326) Switching conditions indicator: LED only for ordering suffix G Max. switching voltage without LED: 100 VAC/DC Max. switching voltage with LED 24 VDC Max. switching voltage with connector: 60 VAC/DC Max. switching current without LED: 400 mA ordering suffix -2187: 250 mA Max. switching current with LED: 10 mA Max. switching capacity without LED: 10 W ordering suffix -2187: 3 W Max. switching capacity with LED: 240 mW Output: - Ue: - Ie: - | | |
| | | |
| | | Connector 1 NO/ 1 NC 13 , ,-^14 [гТс^п 22 | | |
| | | |
| | | • With coding • Long life, no mechanical wear • Protection class IP 67 • Actuation only possible with BPS 33 • Intensitive to transverse misalignment • Concealed mounting possible • Intensitive to soiling • AS-Interface Safety at Work available, see chapter 5 | | |
| | | 1 NO/2 NC 32j-^J-1 c | | |
| | | |
| | | |
| | | |
| | | Ambient temperature: Storage and transport temperature: Repeat accuracy R: Max. switching frequency: Resistance to shock: Resistance to vibration: | | - 25 °C ... + 70 °C - 25 °C ... + 70 °C < 0.1 x Sao approx. 1 kHz 30 g / 11 ms 10 ... 55 Hz, amplitude 1 mm | | |
| | | | | | | | | | Approvals | | | | | H C D | | | | | Ordering details | | | | BNS 33-©z©-®-® | | | | | No. Replace Description | | | | | | | | | | |
| | | |
| | | |
| | | Note | | |
| | | |
| | | Contact symbols shown for the closed condition of the guard device. The contact configuration for versions with or without LED is identical. The LED is illuminated when the guard door is open. | | |
| | | |
| | | 02 11 12 | | 2 NC 1 NO/1 NC 1 NO / 2 NC Without LED With LED With cable With connector M8 (only for 1 NO / 1 NC, 1 NO / 2 NC) Individual contact outlet Individual contact outlet, LED in NO path Actuation from cable direction | | |
| | | |
| | | G | | |
| | | |
| | | |
| | | ST | | |
| | | |
| | | Enabling zone | | |
| | | 2187 2187-10 2237 | | |
| | | |
| | | |
| | | |
| | | 1-82 | | |
| | | SCHmERSRL | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |