Standards:IEC/EN 60204-1EN 60947-5-3EN 954-1BG-GS-ET-14 BG-GS-ET-20 Stop category0 Control category:1 to EN 954-1 Start conditions:Automatic Start-up test:no Enclosure:glass-fibre reinforced thermoplastic Mounting:snaps onto standard DIN rail to EN 50022 Termination:screw terminals •Control Category 1 to EN 954-1•Classification PDF-S to EN 60947-5-3 incombination with BNS safety sensors•1 enabling path
•Monitoring of BNS range magnetic safety sensors•LED function display•Various operating voltages available Cable section:max. 2.5 mm >
2 (incl. conductor ferrules)Protection class:terminals IP 20 enclosure IP 40 to EN 60529U >
e :AES 1112: 24 VDC ±15 %AES 1112.1: 110 VAC
AES 1112.2: 230 VACAES 1112.3: 24 VAC AES 1112.4: 42 VAC I >
e :0.03 A Power consumption:0.7 W Monitored inputs2 x 1 NC / 1 NO Feedback circuit:no Max. cable length:1000 m of 0.75 mm >
2 conductor Enabling contacts:1 enabling path Utilisation category:AC-15, DC-13I >
e /U >
e :1.5 A / 250 VAC 1 A / 24 VDC Contact load capacity:max. 250 VAC, max. 4 A (cos >
Ï•
= 1) Max.
industrial fuse rating:4 A gL/gG D-fuse Function display:LED EMC rating:conforming to EMC Directive Max. switching frequency:10 Hz Overvoltage category:II to DIN VDE 0110 Degree of pollution:3 to DIN VDE 0110 Resistance to vibration:10 ... 55 Hz / amplitude 0.35 mm, ±15 % Resistance to shock:30 g / 11 ms Ambient temperature:0 °C … + 55 ºC Storage and transport temperature:– 25 °C … + 70 ºC Dimensions:22.5 x 75 x 110 mmNote:Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. Approvals >
H C D
Ordering details
AES 1112 >
➀
No. Replace Description >
➀
24 VDC.1110 VAC.2230 VAC
.324 VAC.442 VAC >
1-100