Inductive proximity switches / AC 2-wire IFL M 30 Technical data Contact variants
Standards:IEC/EN 60947-5-2 VDE 0660-208S IFL 10-30-01T-1310IFL 10-30-10T-1310
IFL 15-30-01T-1310
IFL 15-30-10T-1310 >
BN L1N n :IFL 10-...: 10 mm, embeddableIFL 15-...: 15 mm, non-embeddableSwitching element function:A: normally open contact or B: normally closed contactSwitching output:F: 2-wire ACU >
BU NC b :90 ... 250 VACRated supply frequency:45 ... 65 HzI >
BN L1N BU e : ≤ 70 °C: max. 200 mA> 70 °C: max. 50 mAI >
NO r :5 mA (220 V)U >
536 d :approx. 8 VProtection circuit:inductive interference protectionU >
Ø13,5Ø11 BN L1N Ø28 imp :4 kVAmbient temperature:0 °C … + 110 ºC (dry heat)Switching frequency f:approx. 10 HzProtection class:IP 67 to EN 60529Protection class:II, >
M30x1,5 BU NC 6 7010080152000LED X Material:housing and nuts:nickel plated brassTightening torque for nuts:A/F 36 max. 3000 NcmConnection:silicone cable 2 x 0.5 mm >
BN L1N • Metal enclosure• Design M 30 x 1.5• Cable with strain relief
• AC 2-wire• Max. + 110 °C (230 °F)LED may become defective when operatedabove 90 °C. Operation of the switch, however, is not affected. >
BU NO 2 , length 2 m, with strain reliefNote:Instead of nuts, a mounting clamp can be provided (see accessories). >
IFL M 30 Technical data Contact variants
Standards:IEC/EN 60947-5-2 VDE 0660-208S IFL 15-300-01TIFL 15-300-10T >
BN L1N n :15 mm, non-embeddableSwitching element function:A: normally open contact or B: normally closed contactSwitching output:F: 2-wire ACU >
BU NC b :15 ... 250 VACRated supply frequency:45 ... 65 HzI >
BN L1N e :500 mAI >
BU m :10 mAI >
NO r :1 mAU >
d :approx. 4.5 V (250 V/200 mA)Protection circuit:inductive interference protection, on request: Short-circuit and overload-proof (ordering suffix -1522) Ie = max. 150 mA, Ud = approx. 7.5 V (150 mA)U >
LED 536 Ø9,5Ø8,6 M30x1,5Ø28 7069883122000 imp :4 kVAmbient temperature:– 25 °C … + 70 ºCSwitching frequency f:approx. 10 HzProtection class:IP 67 to EN 60529Protection class:II, X •
Thermoplastic enclosure• Design M 30 x 1.5• Cable with strain relief• AC 2-wire Material:housing and nuts: thermoplastic (PBTP + PA 12)washer: rubber (perbunan)Tightening torque for nuts:A/F 36 max. 400 NcmConnection:cable H03VV-F 2 x 0.5 mm >
2 , length 2 m, with strain reliefNote:Instead of nuts, a mounting clamp can be provided (see accessories). >