Inductive proximity switches / DC 3-wire IFL M 30 Technical data Contact variants
Standards:IEC/EN 60947-5-2 VDE 0660-208S IFL 15-300L-10/01NIFL 15-300L-10/01P >
1 L+L n :15 mm, non-embeddableSwitching element function:P: normally open contact or normally closed contact(Programmable by repositioning the plug-in jumper at the terminal screws)Switching output:P: 3-wire DCN: 3-wire DCU >
2/4 3 NONC – 1 L+L 2/4 3 b :10 ... 60 VDCI >
NONC – e :400 mAI >
:approx. 5.5 mA (24 V)U >
636 d :approx. 1.5 V (400 mA)Protection circuit:wrong polarity andinductive interference protection, on request: short-circuit and overload proof(Index -1665-1) Ie = 300 mA, Ud = approx. 1 V (300 mA)Ambient temperature:– 25 °C … + 70 ºCSwitching frequency f:approx. 100 HzProtection class:IP 67 to EN 60529Protection class:II, >
LEDM16x1,5 46 20 M30x1,5 45° 9870118 X •
Thermoplastic enclosure• Design M 30 x 1.5• Wiring compartment
• DC 3-wire Material:housing and nuts: thermoplastic (PBTP + PA 12)washer: rubber (perbunan)Tightening torque for nuts:A/F 36 max. 400 NcmConnection:Terminal screws for max. 1.5 mm >
2 , with cable entry M16 x 1.5Note:Instead of nuts, a mounting clamp can be provided (see accessories). Programmable by reposi-tioning the plug-in jumperat the terminal screws >
NC r SchließerÖffne
NO IFL 40 x 25 x 12 mm Technical data Contact variants
Standards:IEC/EN 60947-5-2 VDE 0660-208S IFL 2-250-10NIFL 2-250-10PIFL 4-250-10NIFL 4-250-10P >
BN L+L n :IFL 2-...: 2 mm, embeddableIFL 4-...: 4 mm, non-embeddableSwitching element function:A: normally open contact(on request: normally closed contact (-01) is available)Switching output:P: 3-wire DCN: 3-wire DCU >
BK BU NO – BN L+L BK BU b :10 ... 30 VDCI >
NO – e :200 mAI >
:approx. 3 mA (24 V)U >
d :approx. 1.2 V (200 mA)Protection circuit:wrong polarity, inductive interference, industrial transients and short-circuit protectionAmbient temperature:– 25 °C … + 70 ºCSwitching frequency f:P: approx. 1 kHz, N: approx. 800 HzProtection class:IP 67 to EN 60529Protection class:II, >
BN L+L LED BK BU 32
6
8,4
40
16104Ø93,2 NO – 6*12172542000M3x6 X >
BN L+L Material:housing: thermoplastic (PBTP), with 2 screws M3 x 6 for rear mountingConnection:cable LiYY 3 x 0.34 mm >
BK • Thermoplastic enclosure• Rectangular design 250 (40 x 25 x 12 mm)• Cable• DC 3-wireSwitches can be mounted adjacent to eachother without interference. >
BU NO – 2 , length 2 mNote:* maximum screwing depth: 6 mm >