Inductive proximity switches / DC 2-wire IFL 40 x 25 x 12 mm Technical data Contact variants
Standards:IEC/EN 60947-5-2 VDE 0660-208S IFL 4-250-10D >
BN L+L n :4 mm, non-embeddableSwitching element function:A: normally open contactSwitching output:D: 2-wire DCU >
BU NO – b :10 ... 40 VDCI >
e :200 mAI >
m :5 mAI >
r :approx. 0.5 mAU >
d : ≤ 6 V (200 mA) ≤ 5.5 V (100 mA)Protection circuit:wrong polarity, inductive interference, industrial transients and short-circuit protectionAmbient temperature:– 25 °C … + 70 ºCSwitching frequency f:approx. 1 kHzProtection class:IP 67 to EN 60529Protection class:II, >
LED 32
6
8,4
40
16104Ø93,2 X >
6*12172542000M3x6 Material:housing: thermoplastic (PBTP), with 2 screws M3 x 6for rear mountingConnection:cable H03VV-F 2 x 0.5 mm >
2 , length 2 m •
Thermoplastic enclosure• Rectangular design 250 (40 x 25 x 12 mm)• Cable
• DC 2-wire >
IFL 112 x 40 x 40 mm Technical data Contact variants
Standards:IEC/EN 60947-5-2 VDE 0660-208S IFL 20-333-10D >
1 L+L n :20 mm, non-embeddableSwitching element function:A: normally open contactSwitching output:D: 2-wire DCU >
4 NO – b :15 ... 150 VDCI >
e :200 mAI >
m :5 mAI >
r :approx. 1 mAU >
d :approx. 8.5 V (200 mA)Protection circuit:wrong polarity and inductiveinterference protectionAmbient temperature:– 25 °C … + 70 ºCSwitching frequency f:approx. 40 HzProtection class:IP 65 to EN 60529Protection class:II, >
40
30LEDM20x1,534,5
40 5,360451127,3 X Material:housing: thermoplastic (PBTP)cover: LuranConnection:Terminal screws with self-lifting pressure clampsfor max. 2 x 1.5 mm >
2 , with cable entry M20 x 1.5 • Thermoplastic enclosure• Rectangular design 333 (112 x 40 x 40 mm)• Wiring compartment• DC 2-wireBy repositioning the switch five differentactuating directions can be selected. Theselected actuating direction can be marked
with a sticker. >
2-17