| | | Standards: Design: Enclosure: Protection class: Termination: Mode of operation: Switching voltage: Switching current: Switching capacity: Dielectric strength: Switching time "Close": Switching time "Open": Bounce duration: Ambient temperature: Mechanical life: Electrical life: Resistance to shock: Resistance to vibration: | | IEC/EN 60947-5-1 rectangular glass-fibre reinforced thermoplastic IP 67 to EN 60529 ble LiYY 2 x 0.25 mm2, length 1 m magnetic max. 250 VAC max. 0.5 A max. 10 VA, 8 W > 450 VAC (50 Hz) max. 2 ms max. 0.07 ms max. 0.5 ms - 25 °C ... + 75 °C 1 billion operations 5 million operations, depending on load 15 g on sine wave oscillation 15 g on sine wave | | 1 NC contact BN 80-01z with N-S actuating magnet | | |
| | | • Flat design • Long life • Non-contacting principle • 1 Reed contact • Actuating distance up to 60 mm depending on actuating magnet and version • Actuating surface marked by protrusion • Pre-wired cable available, cable length 1 m • Protection class IP 67 | | |