| | | Foot switch | | |
| | | |
| | | KF and KFS | | Contact variants | | |
| | | Technical data | | |
| | | |
| | | Standards: IEC/EN 60947-5-1 VDE 0113 part 1
| | 1 NO | | |
| | | |
| | | |
| | | Enclosure: | | nylon 66, glass-fibre
| |
| | | |
| | | reinforced, self-extinguishing
| |
| | | |
| | | Pedal: | | glass-fibre reinforced
| | 2 NO bJL-Jbk bTT bu | | |
| | | |
| | | thermoplastic (Nylon 66)
| | |
| | | |
| | | Protective shield: | | KF: - | | |
| | | |
| | | |
| | | KFS: stainless-steel casing, enamelled | | |
| | | |
| | | Termination: Cable section: Protection class: Switching system: | | cable H03W-F, length 2 m 0.5 mm2 IP 65 to EN 60529 reed contacts or
| | Change-over contact 1__2 bu bn 3bk | | |
| | | |
| | | |
| | | |
| | | snap action, change-over contact | | 1 NO PNP gn | | |
| | | |
| | | |
| | | Switching voltage: Max. making current: Max. switching capacity: | | reed contacts: 12 ... 250 VAC/DC reed contacts: 1 A micro-break switches: 5 A reed contacts: | | |
| | | but | | |
| | | wh | | |
| | | |
| | | 1 NO NPN bn | | |
| | | |
| | | out | | |
| | | wh | | |
| | | |
| | | |
| | | |
| | | |
| | | 30 VA micro-break switches: 1250 VA Ambient temperature: - 10 °C ... + 70 °C Mechanical life: > 1 million operations | | |
| | | 2 contacts Thermoplastic enclosure Protective metal shield Small flat design With or without protective shield Reed contacts for low switching currents from 1 mA to 1 A Micro-break switches for switching currents up to 5 A Pre-wired cable available, cable length 2 m Hall sensors available giving analogue output signal proportional to pedal deflection Execution with pressure point (2-stage switch) possible Plug-in connection possible Other cable types/lengths possible Available with special finish in RAL colour tones | | |
| | | |
| | | • | | |
| | | |
| | | • | | |
| | | |
| | | |
| | | | | | | | | | | Approvals | | | | | H ® D | C€ | | | | Ordering details | | | | KF©@ | | | | | No. | Replace | Description | | | | | | Without protective shield | | | | | S | With protective shield | | | | | | Reed contacts: | | | | | 1S | 1 NO contact | | | | | 2S | 2 NO contacts | | | | | 1W | 1 change-over contact | | | | | | | | | | | 1PW | 1 change-over contact | | | | | 1S PNP | 1 PNP NO contact | | | | | 1S NPN | 1 NPN NO contact | | | | 5CH | T1ER5RL | | | | | | | | | | | |
| | | 3-11 | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |