| | | Emergency-Stop push button | | |
| | | |
| | | EDRRS 40 RT | | |
| | | EDRRZ 40 RT | | | Technical data | | |
| | | |
| | | Standards: Operators: Protection class: Contact material: Switching system: Contact type: | | IEC/EN 60947-5-5 EN 418 aluminium IP 65 to EN 60529 silver 0 IEC 60947-5-1 slow action change-over contact, 2 NC contacts combined as desired screw terminals WAGO clip-in terminals on request max. 2.5 mm2 10 A 400 V 8 A / 230 VAC 5 A / 24 VDC AC-15, DC-13 10 A (slow blow) > 2 x 1.25 mm < 5 ms at 100 mm/s - 25 °C ... + 80 °C (-40 °C on request) operators: > 100,000 operations / contact blocks: 10 million operations 1200/h max. 70 g / 4 ms, contact block: 110 g / 4 ms 38.5 mm 22.3 mm | | |
| | | |
| | | Termination: | | |
| | | |
| | | Cable section: Ithe: Ui: Ie/Ue: Utilisation category: Max. industrial fuse rating: Contact opening: Bounce duration: Ambient temperature: Mechanical life: | | |
| | | • To EN 418 / IEC 60947-5-5 • Max. 2 NC and 2 NO or 4 NC contacts • Projection from front of panel 29 mm • For mounting holes 0 22.3 mm • Selection of terminal designations available • Pull to reset | | • Reset by key • To EN 418 / IEC 60947-5-5 | | |
| | | |
| | | |
| | | Switching frequency: Resistance to shock: | | |
| | | |
| | | |
| | | Push button 0: Mounting hole 0: | | |
| | | |
| | | |
| | | | | | | | | | | Approvals | | | | | D ® | | | | | Ordering details | | | | EDRR© 40 RT/©/©/® | | | | No. | Replace | Description | | | | | Z | Pull reset | | | | | S | Key reset | | | | | EF 303.1 | 1 NO / 1 NC | | | | | EF 303.2 | 1 NO / 1 NC | | | | | EF 220.1 | 2 NC | | | | | EF 220.2 | 2 NC | | | | | | Contact labelling, | | | | | | see contact variants | | | | ® | EFR | Spring element | | | | | | (always to be ordered) | | | | | | | | | | |
| | | Approvals | | |
| | | |
| | | Note | | Note | | |
| | | |
| | | Other product variants: • Diameter 16.2 mm and 30.5 mm • Different diameters for the actuating heads • Contact elements with push-on spades and (WAGO cage clamps) • Optionally also completely mounted List D-Z.97 and List D-22.G ELAN, Wettenberg | | In order to avoid repeating of the same terminal designations in wiring diagrams, contact blocks with the same contact configuration are available with different terminal designations. Max. 2 NC and 2 NO or 4 NC contacts | | |
| | | |
| | | |
| | | |
| | | 2-11 | | |
| | | BCHFT1ER5RL | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |