Safety in System Protection for man and machine SERIAL DIAGNOSTICS THE SAFETY SOLUTION FOR INCREASED AVAILABILITY
Open the catalog to page 1SYSTEM OVERVIEW FOR THE COMPONENT TO THE SUPERIOR MACHINE CONTROL SYSTEM Superior machine control system SD gateways and safety controllers Safety controller PROTECT PSC1 Universal gateway SD-I-U PROFIBUS gateway SD-I-DP Installation systems Passive Distribution Module Electronic safety switchgear with SD interface
Open the catalog to page 2sd interface for electronic safety sensors and interlocks Electronic safety sensors and interlocks with SD interface are capable of transmitting comprehensive status and diagnostics data to a superior machine control system. The data from series-connected safety switchgear are sent to a SD gateway via the SD bus and transmitted to industrial field bus protocols. The SD interface also allows safety interlocks to be locked and unlocked individually, as well as configured. As such, the latching force of the MZM100-SD electromagnetic solenoid interlock can be set by SD interface. benefits of the...
Open the catalog to page 3INSTALLATION SYSTEMS SMOOTH AND FAIL-SAFE INSTALLATION SIMPLE DATA TRANSMISSION VIA SD INTERFACE Mixed installation of electronic safety sensors and interlocks to form a safety function can be realised easily in the field with the SD interface. The actuating and diagnostics data are transferred in the SD interface in series via one wire between the SD gateway and the SD slave. Communication with up to 31 slaves per SD gateway possible. These can also be divided into several different safety functions as required. Addressing of the SD slaves takes place automatically. There are two options for...
Open the catalog to page 4INSTALLATION SYSTEMS SMOOTH AND FAIL-SAFE INSTALLATION ENHANCED STATUS AND DIAGNOSTICS INFORMATION There is a difference between regular status information and diagnostics information in safety switchgear. In safety sensors and interlocks, status information includes changes to the safety guard position and door locking: ■ Safety guard closed/open Diagnostics information can be divided into safety-critical and non-safety-critical errors. With non-safety-critical errors, an error warning is output. The safety outputs are switched off only when 30 minutes have elapsed. In the event of safetycritical...
Open the catalog to page 5The safe inputs and outputs as well as the SD bus inputs and outputs of the safety switchgear are switched in series with the aid of the installation systems. Three different installation solutions are available for the installation: The installation system with SD junction box enables quick wiring between safety switchgear devices: The cables with M12 connectors are routed directly from one safety switchgear device to the next and can be routed in the cable channel with SD junction boxes. ■ Passive Distribution Module PDM sd junction boxes ■ Y-adapter for series wiring ■ Component wiring in...
Open the catalog to page 6passive field box pfb The passive field box PFB allows switchgear devices to be connected to a central point in the field. The 8-pin M12 device connections on the passive field box are protected with self-resetting fuses. Additional LEDs are available for each device connection ■ Green LED: fuse status ■ Yellow LED: safety release of connected device passive field box pfb ■ Passive fieldbox for series-wiring ■ Heavy duty IP67 version for installation in the field ■ For up to 4 electronic safety switchgear from Schmersal
Open the catalog to page 7The passive distribution module allows the safety switchgear devices to be wired into a single switch cabinet. The distribution module features four device connections with cage clamps and can be fixed to a 35 mm rail The device connections of the PDM are protected by selfresetting fuses. The status of each fuse is indicated by a green LED. passive distribution module pdm ■ Passive distribution module for series wiring ■ For installation in terminal boxes ■ For up to 4 electronic safety switchgear from Schmersal
Open the catalog to page 8communication Pure SD gateways or safety controllers with integrated SD gateway are available to convert the SD bus protocol into standard protocols. ■ UNIVERSAL gateway or PROFIBUS gateway ■ Programmable safety controllers with integrated gateway field bus gateway sdg ■ Conversion of status and diagnostics data to Ethernet-based fieldbus protocols ■ Serial diagnosis of max. 31 safety switchgears ■ Diagnostic and configuration interface for easy commissioning and maintenance of the system CflNopsra programmable safety controllers psci-c-io and psci-c-ioo ■ Evaluation of safety-related signals...
Open the catalog to page 9safety switchgear The range of SD-capable safety switchgear ranges from safety sensors to solenoid interlocks1) and SD-capable control panels. Devices can be connected to the SD bus easily and reliably via 8-pin M12 male connectors. ■ With and without magnetic latching ■ Assured switching distance Sao 12 mm (with latching: 5 mm) ■ Assured switch-off distance Sar 30 mm II SAFETY SENSOR RSS36 ■ Assured switching distance Sao 10 mm ■ Assured switch-off distance Sar 20 mm ■ With magnetic latching SAFETY SENSOR RSS260 ■ Extremely compact design ■ Assured switching distance Sao front 10 mm, side 6...
Open the catalog to page 10■ Individual coding possible ■ 2 safety outputs and SD interface ■ Manual release, emergency exit or emergency release ■ 3 different directions of actuation SOLENOID INTERLOCK AZM201 ■ Holding force 2,000 N ■ Individual coding possible ■ 2 safety outputs and SD interface ■ Manual release, emergency exit or emergency release SOLENOID INTERLOCK MZM100 ■ Holding force 750 N ■ Latching force can be set via SD interface ■ 2 safety outputs and SD interface CONTROL PANEL BDF200 ■ Control panel with emergency stop and 3 control elements ■ For mounting on commercially available aluminium profile systems...
Open the catalog to page 11SAFETY SERVICES ■ tec.nicum academy -Seminars and training ■ tec.nicum consulting -Consultancy services ■ tec.nicum engineering -Design and technical planning ■ tec.nicum integration -Execution and installation THE SCHMERSAL GROUP PROTECTION FOR MAN AND MACHINE In the demanding field of machine safety, the owner-managed Schmersal Group is one of the international market leaders. The company, which was founded in 1945, has a workforce of about 2,000 people and seven manufacturing sites on three continents along with its own companies and sales partners in more than 60 nations. Customers of the...
Open the catalog to page 1236 Pages
146 Pages
4 Pages
24 Pages
2 Pages
28 Pages
296 Pages
28 Pages
36 Pages
124 Pages
28 Pages
10 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
24 Pages