You may also be interested in
Control foot-switch, Emergency stop, Emergency stop switch, Proximity sensor, Safety module
Text version of the page
5
Less installation time with
AS-Interface Safety at Work
Easier and quicker with ASInterface
SaW: Choose a Safety
device – Connect it to the yellow
AS-Interface cable – Configure
the safety function in the safety
monitor. – That’s it.
AS-Interface SaW
System Features
• Up to 31 standard and
safety slaves on the
AS-Interface system
• No Safety PLC
necessary
• Safety-relevant signals
can be allocated into
groups and multiple
Safety monitors may
be connected
• Response time is
max. 40 ms
• Safety-relevant signals
can be integrated into
plant diagnostics
• Certified up to
- PL e/category 4
in accordance with
EN ISO 13849-1
- SIL 3 in accordance
with IEC 61508
• Certified by the TÜV
(German Technical
Inspectorate)
No further settings are required
at each of the safety devices,
the bulky parallel wire cables
between the safety devices in
the field and the switching cabinet
are reduced and wiring time is
decreased. The power supply
for all safety sensors is supplied
over the single yellow AS-Interface
cable.
R C
S OR
Safety
guard
monitoring
Controller
E-Stop
Command
Standard AS-Interface Module
Safety
monitor
AS-i
Master
Position
switch
Safety
light curtain
AS-i
Power
Two-Hand
Control
AS-Interface Safety at Work overview
ble
|
|